transceiver and interface for CAN-bus
communication. The charger's LEDs indicate the
status of the charging process.
Receiving
On receipt, visually inspect the product for any
physical damage. If necessary, contact the
transport company.
Check the delivered parts against the delivery
note. Contact your supplier if something is
missing, see Contact information.
Installation
NOTE
Installation may only be performed by a qualified
service partner.
Mechanical installation
The battery charger is designed only for
indoor use unless the charger is at least IPX4-
rated.
Attach and secure the battery charger to a
wall with screws (not included).
Comply with the dimensions specified for free
space around the battery charger. See Fig. 2
Installation.
CAUTION
The battery charger may become warm during
use. Ensure ventilation around the charger.
The battery charger should always be
securely fastened. Use screws and lock
washers when attaching the charger.
Electrical overview
See Fig. 3 Connections and components:
1. Negative terminal (−).
2. Positive terminal (+).
3. Fuse, for specifications see Fuse protection.
6
Electrical installation
WARNING
RISK OF ELECTRIC SHOCK!
Incorrect connection of battery cables can cause
personal injuries and damage to the battery,
battery charger and cables.
Make sure the connections are correct.
WARNING
RISK OF ELECTRIC SHOCK!
Risk of live chassis.
Always connect the charger to a power outlet with
protective earth.
1. The battery charger is produced for different
mains voltages. Check that the power supply
at the site of the installation complies with the
rated voltage specified on the battery charg-
er's data label. The label is located on the side
of the charger. The charger is normally
equipped with a fixed mains cable with
connector.
2. Check the polarity of the battery connector
and cable before connecting the battery. The
charger is normally delivered with a battery
cable with the following polarity:
Positive (+) = Red
Negative (−) = Blue or Black
3. Connect the battery cables to the battery.
4. Connect the charger to the BMS.
5. Check adjustments for BMS and charging
process, refer to Safety precautions, Before
start charging.
Operation
User interface - Control panel
See Fig. 1 Control panel
1. Mains indicator (Blue)
2. Charging indicators (LED indication)
3. Pause (stop / resume charging)
4. OK / Select
5. Menu navigation
6. Display