Step 2: Cabinet Preparation
GAS AND ELECTRIC
SUPPLY ZONES:
F_G. 3A Gas & E_ectrica_ Supply
Zones
for AH Gas Ranges
Typical placement shown.
Other placement of
Electrical Supply and
Receptacle within the
Electrical and Gas Supply
Zone is acceptable.
NOTE:
If not already
present, install
gas shut-offvalve
in an easiJy
accessible
location. Make
sure all users
knowwhere and
how to shut off
the gas supply to
the range.
NOTE: The
installershould
inform the
consumer of the
location of the
gasshutzoffvalve.
3/4" Ftex Line to
Appliance
1/2"
NPT
120 VAC Receptacle
(Shown) or Junction
I
Box
I ....
Centerline of
Electrical
I
2" Maximum
Protrusion from Wait
"_
_
a
for Gas Supply
Floor
Model
A
B
C
D
E
30"
8"
12"
10"
6-1/2"
5ol/4"
36"
10ol/2"
15"
10ol/2"
6ol/2"
5ol/4"
48"
16-1/2"
16"
15-1/2"
6ol/2"
5ol/4"
The All Gas ranges
may be con-
nected
to the power
supply with a
range
supply
cord
(supplied
with
range) or by hard-wiring
to the power
supply.
It is the responsibility
of the
installer to provide the proper wiring
components
(cord or conduit
and
wires)
and complete
the gas con-
nection
as dictated
by local codes
and ordinances,
and/or the National
Electric
Code.
The units
must be
properly
grounded.
Refer to Step 6
for details.
The
range
must
be connected
only to the type of gas for which
it is certified.
If the range is to be
connected
to propane
gas, ensure
that the propane
gas supply tank is
equipped with its own high pressure
regulator
in addition to the pressure
regulator
supplied
with the range.
(See Step 5.)
NOTE:Any
opening in the wall behind the appliance
and any opening
in the floor
under the appliance
must be sealed.
mMPORTANT:
The cord supplied with gas ranges having electric griddle requires
a NEMA 5-20 receptacle,
shown here. Local codes may require
a different
wiring method.
NEMA 5z20
RECEPTACLE
PLUG

Publicité