Important Installation Information
GAS type
verification
Verify the type of gas supplied
to the location.
Ensure
that the appliance
is connected
to the type of gas for
which it is certified. All ranges are certified for use with
natural
gas or propane
(LP) gas. Make certain
the
range matches
the gas type available.
Important
*
A backguard must be utilized when there is less than
a 12" horizontal clearance between combustible
ma-
terials and the backedge of the range. The Thermador
Low Back backguard must be ordered separately and
installed at the rear of the range. For island installa-
tions and other installations with more than 12" clear-
ance, an optional stainless steel Island Trim is avail-
able to cover the backguard
mounting flanges.
.
Verify that the appliance
is correct for the type of gas
being provided.
Refer to Step 5 on Page 12 before
proceeding
with the installation.
Gas Supply:
Natural Gas -
6 inch water column. (14.9 mb) min,
14 inch (34.9 rob) max.
Propane Gas - 11 inch water column. (27.4 mb), min,
14 inch (34.9 rob) max.
Electric
Power
Supply:
30" Model:
4 Burners - 120 VAC, 60 Hz, IPh.
15Amp circuit.
36" Models:
6 Burners-
120 VAC, 60 Hz., IPh,
15Amp circuit.
4 Burners with Grill- 120 VAC, 60 Hz, 1Ph, 15 Amp circuit.
4 Burners with Griddle-
120 VAC, 60 Hz, IPh, 20 Amp
circuit.
48" Models:
6 Burners with Grill- 120 VAC, 60 Hz, 1Ph. 15 Amp circuit.
6 Burners with Griddle-
120 VAC, 60 Hz. IPh. 20 Amp
circuit.
4 Burnerswith
Grill and Griddle- 120 VAC, 60 Hz, 1Ph, 20
Amp circuit.
CAUTION
When connecting
the unit to propane gas, make
certain the propane gas tank is equipped
with its
own high-pressure
regulator
in addition
to the
pressure
regulator
supplied
with the range. The
maximum
gas
pressure
to
this
appliance
must
not exceed
14.0 inches
water
column
(34.9 rob) from the propane
gas tank
to the
pressure
regulator.
CAUTION
This unit is designed
as a cooking
appliance.
Based on safety considerations,
never use it for
warming
or heating
a room.
This appliance complies with one or more of the following
standards:
UL 858, Standard for the Safety of Household Electric
Ranges
UL 923, Standard for the Safety of Microwave Cooking
Appliances
UL 507, Standard for the Safety of Electric Fans
ANSi Z21.1, American National Standard for House-
hold Cooking Gas Appliances
CANiCSA-C22.2
No. 113-M1984
Fans and Ventila-
tors
CAN/CSA-C22.2
No. 61-M89
Household
Cooking
Ranges
It is strong_
recommended
that this appliance
be
installed
in conjunction
with a suitable overhead
vent
hood. (See Step 1 for Ventilation
Requirements.)
Due
to the high heat capability
of this unit, particular
atten-
tion should be paid to the hood and duct work instal-
lation to assure it meets local building
codes.
It is the responsibility
of the owner and the installer to
determine
if additional
requirements
and!or standards
apply to specific
installations.
CAUTION
To eliminate
risk of burns
or fire caused
by
reaching
over
heated
surface
units,
cabinet
storage
located
above
the
surface
units
should
be avoided.
Check
local building
codes for the proper method of
appliance
installation.
Local codes vary. Installation,
electrical
connections
and grounding
must comply
with
all applicable
codes.
In the absence
of local
codes
the appliance
should
be installed
in accor-
dance with the National Fuel Gas Code ANSI Z223.1/
NFPA 54 current issue and National
Electrical
Code
ANSI/NFPA
70-current
issue. In Canada,
installation
must be in accordance
with the CAN 1-B149.1
and .2
-Installation
Codes for Gas Burning Appliances
and/
or local codes.

Publicité

loading

Ce manuel est également adapté pour:

Professional pro-grand pg36Professional pro-grand pg48