Step 5:
Verify the type of gas being used at the installation
site.
As shipped
from the factory,
units
are configured
for use with only natural
gas or propane
(LP) gas.
Make certain
the range
matches
the type of gas
available
at this location.
These
ranges
are NOT
convertible
between
different
types
of gas.
For installation
of the appliance
at high altitude, please
consult your local gas company
for their recommen-
dation
of the
correct
orifice
sizes
and
any other
necessary
adjustments
that will provide
proper gas
combustion
at specified
altitudes.
CAUTION
When
connecting
unit to propane
gas,
make
certain the propane gas tank is equipped
with its
own high pressure
regulator
in addition
to the
pressure
regulator
supplied
with the appliance.
The pressure
of the gas supplied
to the appli-
ance
regulator
must
not
exceed
14"
(34.9
mb) water column.
Supply
Pressure:
Manifold
Pressure:
Natural
Gas Requirements:
Inlet Connection:
3/4" NPT external
1/2" NPT internal
(Minimum
3/4" dia. flex line.)
6" min. to 14" max. water column.
(14.9 to 34.9 mb)
5" water column
(12.5 mb)
Supply
Pressure:
Manifold
Pressure:
Propane
Gas Requirements:
Inlet Connection:
3/4" NPT external
1/2" NPT internal
(Minimum
3,14 '' dia. flex line.)
11" min. to 14" max. water column.
(27.4 mb to 34.9 mb)
10" water column
(24.9 mb)
WARNING
Gas Requirements and Hookup
HOOK
UP
A manual
gas shut-off
valve
must
be installed
external to the appliance,
in a location accessible
from the front, for the purpose
of shutting
off the
gas supply. The supply line must not interfere with
the back of the unit. Make sure the gas supply is
turned
off at the manual
shut-off
valve
before
connecting
the appliance.
The range is supplied
with its own pressure
regu-
lator that has been permanently
mounted
within
the range body.
Use 3/4" flex line to connect
between
the gas
supply and the appliance
inlet pipe, which exits the
upper rear of the appliance.
The appliance
pipe
connection
has a 3/4" NPT external
thread and a
1/2" NPT internal
thread.
(See Photo
A.) Use
caution
to avoid crimping
the 3/4" flex line when
making
bends.
The gas supply connections
shall be made by a
competent
technician
and in accordance
with
local codes or ordinances.
In the absence
of a
local code, the installation
must conform
to the
National
Fuel Gas Code ANSI Z223.1iNFPA54-
current
issue.
Always
use pipe sealing
compound
or Teflon®
tape on the pipe threads,
and be careful
not to
apply
excessive
pressure
when
tightening
the
fittings.
Leak testing
of the appliance
shall be in accor-
dance with the following
instructions.
• Turn on gas and check supply line connections
for beaks using a soap and water solution,
Bubbles
forming
indicate
a gas leak. Repair all
beaks immediately
after finding
them.
• Do not use a flame
of any kind to check
for
gas leaks.
Photo
A
Gas line must not come
in contact
with any
components
inside back cover of range.
Run
gas line in channel
in back of range.
Use 3/4" flex line to connect between the gas supply
and the appliance
manifold
pipe, which exits the
upper left rear of the appliance.
12