Step 6: Electrical Requirements, Connection & Grounding
Before
installing,
turn power OFF at the service
panel. Lock service
panel to prevent
power from
being turned ON accidentally.
Chart
B: Electrica_
Suppmy Circuit
Requirements
MODEL TYPE
VOLTAGE
CURRENTRATING
FREQUENCY
PHASE
30"
120 VAC
15 Amps
60 Hz.
Single
36"
120 VAC
15 Amps
60 Hz.
Single
36" with Grill
120VAC
15 Amps
60 Hz.
Single
36" with Griddle
120 VAC
20 Amps
60 Hz.
Single
48" with Grill
120VAC
15 Amps
60 Hz.
Single
48" with Griddle
120 VAC
20 Amps
60 Hz.
Single
48" with Grill
120 VAC
20 Amps
60 Hz.
Single
and Griddle
A neutral
supply wire must be provided
from the
power source (breaker/fuse
panel) because
criti-
cal range
components,
including
the
surface
burner
spark
re-ignition
modules,
require
120
VAC to operate safely and properly. An improper
120 VAC power
supply will cause
malfunction,
damage
to this appliance,
and possibly
create a
condition
of shock
hazard.
If the correct
power
supply circuit is not provided,
it is the responsibil-
ity and obligation
of the installer and user to have
proper
power
supply
connected.
This must be
accomplished
in accordance
with all applicable
local codes and ordinances
by a qualified
electri-
cian.
In the absence
of local codes
and ordi-
nances,
the power supply connection
shall be in
accordance
with the National
Electrical
Code.
Observe
all governing
codes
and ordinances
when grounding.
In the absence
of these codes
or ordinances
observe
National
Electrical
Code
ANSI/NFPA
No. 70 current issue.
Electric
wiring
diagrams
and schematics
have
been placed
in the toe kick area of the range for
access
by a qualified
service
technician.
iMPORTANT
For all gas ranges
with electric
griddle,
dedicated
20 AMP service
is required for proper operation.
Before you plug in an electrical
cord, be sure all controls
are in the OFF position.
For appliances
equipped
with a cord and plug, do not cut or remove the ground prong. It must be plugged into
a matching
grounding
type receptacle
to avoid electrical
shock. If there is any doubt as to whether
the wall
receptacle
is properly
grounded,
the customer
should have it checked
by a qualified
electrician.
Installer - show the owner the location
of the circuit breaker
or fuse. Mark it for easy reference.
_,
CAUTION
The appliance
must be isolated from the gas supply piping system by closing its individual
manual shut-
off valve during any pressure
testing of the gas supply piping system at test pressures
equal to or less
than 1/2 psig (3.5kPa.).
The appliance
and its individual
shut off valve must be disconnected
from the gas supply piping system
during any pressure
testing of the system
at test pressures
in excess
of 1/2 psig (3.5kPa.).
When checking the manifold gas pressure,
the inlet pressure to the regulator
should be at least 6.0" (14.9
mb) W.C. for natural gas or 11.0" (27.4 mb) for propane.
Do not attempt
any adjustment
of the pressure
regulator.
13