Step 2: Cabinet Preparation
.
.
The range is a free standing
unit. If the unit is to
be placed
adjacent
to cabinets,
the clearances
shown
in Fig. 1 are required.
The same clear-
ances apply to island installations,
except for the
overhead
cabinets,
which
must have
a space
wide enough to accept the flared island hood as
indicated
in Fig. 1.
The 36" ranges
may be recessed
into the cabk
nets beyond the edge of the front face of the oven
(See Figures 2A and 2B). The 30" and 48" ranges
are not approved
to be installed
flush with the
cabinets.
CAUTION
In these installations,
the door and cabinet on
36-inch models can cause a pinching hazard.
3.
The gas and electrical
supply should be within the
zones shown in Fig. 3A.
.
5.
.
.
.
Any openings
in the wall behind the range and in
the floor under the range must be sealed.
When
there is less than a 12" horizontal
clear-
ance between
combustible
material
A and the
back edge of the range above the cooking
sur-
face,
a Thermador
Low Back or Pot and Pan
Shelf
must
be installed.
(See Fig. 2A).
When
clearance
to combustible
material
A is over 12",
a Thermador
Island Trim may be used. (See Fig.
2B). Figures
2A and 2B indicate
the space
re-
quired for each type of backguard.
A three
(3) inch minimum
clearance
is needed
when the range is installed
beside a combustible
side wall.
Always
keep appliance
area clear and free from
combustible
materials,
gasoline
and other flam-
mable vapors and liquids.
Do not obstruct
the flow of combustion
and ven-
tilation air to the unit.
Note:
The maximum
depth
of over head cabinets
installed
on either side of the hood is 13".
A 36-inch
minimum
clearance
is required
between
the top of the range and the bottom of an unprotected
cabinet.
It is recommended
that the bottom
of the
wood or metal cabinet be protected
by not less than
1,1'4 inch of a flame retardant
material covered with not
less than No. 28 MSG sheet steel, 0.015 inch (0.38
mm) thick stainless
steel, 0.024 inch (0.6 mm) alumk
num, or 0.020
inch (0.5 mm) thick copper.
Flame
retardant
materials
bear the following
mark:
UNDERWRITERS
LABORATORIES
INC.
CLASSIFIED
MINERAL
AND FIBER
BOARDS
SURFACE
BURNING
CHARACTERISTICS
Followed
by the flame
spread
and smoke
ratings,
these
designations
are shown
as "FHC
(Flame
Spread/Smoke
Developed)."
Materials with "O" flame
spread ratings are flame retardant.
Local codes may
allow other flame spread
ratings.
A
As defined
in the "National
Fuel Gas Code"
(ANSI Z223.1 / NFPA 54, Current Edition).