ExBin-P...
Special options
Technical data
Supply voltage, frequency
Current, power consumption
Galvanic isolation
Electrical connection
Cable glands
Cable glands ...-CT
...-VA, ...-OCT, ...-OVA 2 × M20 × 1,5 mm, Ex-e approved, brass nickel-plated, for cable diameter ~ Ø 6...13 mm
Protection class
Display
Control elements
Housing material
Dimensions (L × W × H)
Weight
Ambient temperature
Temperature class
Ambient humidity
Sensor circuit
Sensor
Pressure connection
Measuring range
Response time of sensor
Accuracy of pressure
Setting range hysteresis
Start delay
Start-up bypass time (AUB)
Switch activation delay
Setting zero point
Output
Additional relay output (type ...-2)
Duration of life Mechanical
Electrical (rated load) 100 × 10
Wiring diagram
Scope of delivery
Approbations
ATEX directive
2014/ 34 / EU
EC type-approved
EPS 14 ATEX 1 657
IECEx certified
IECEx EPS 14.0074
Approval for gas
II 2 (1) G Ex e mb [ia Ga] IIC T6...T4 Gb
Types ...-CT, ...-OCT II 2 (1) G Ex e mb [ia Ga] IIB T6 Gb
Approval for dust
II 2 (1) D Ex tb [ia Da] IIIC T80°C...T130°C Db IP66
CE identification
CE № 0158
EMC directive
2014/ 30/ EU
Enclosure protection
IP66 in acc. with EN 60529
EAC
TC RU С-DE.ГБ08.В.01510
Schischek GmbH Germany, Muehlsteig 45, Gewerbegebiet Sued 5, 90579 Langenzenn, Tel. +49 9101 9081-0, Fax +49 9101 9081-77, E-Mail info-de@schischek.com
ExBin-P...-2
...-CT
...-OCT
...-P-100
24 VAC / DC ± 20 % (19,2...28,8 VAC / DC), 50 / 60 Hz
150 mA, ~ 4 W, internal fuse 500 mAT, without bracket, not removable
Supply for relay output min. 1,5 kV
Terminals 0,14...2,5 mm² at integrated Ex-e terminal box, stripping length 9 mm, torque 0,4...0,5 Nm, equipotential bonding 4 mm²
2 × M16 × 1,5 mm, Ex-e approved, for cable diameter ~ Ø 5...9 mm
2 × M16 × 1,5 mm, Ex-e approved, brass nickel-plated, for cable diameter ~ Ø 6...10 mm
Class I (grounded)
LC-Display, backlit, for configuration, user guidance, parameter and actual value indication. Status indicator via LEDs
3 buttons for configuration
Aluminium die-cast housing, coated. Optional with seawater resistant coating (...-CT/...-OCT) or stainless steel housing,
№ 1.4581 / UNS-J92900 / similar AISI 316Nb (...-VA/...-OVA)
Aluminium housing ~ 180 × 107 × 66 mm, stainless steel housing ~ 195 × 127 × 70 mm (each without connectors)
~ 950 g aluminium housing, stainless steel version ~ 2,5 kg
−20...+50 °C, storage temperature −35...+70 °C
Aluminium housing
T6 (T80 °C) at −20...+50 °C
Stainless steel housing T5 (T95 °C) at −20...+40 °C, T4 (T130 °C) at −20...+50 °C
0...95 % rH, non condensing
Internal intrinsically safe (IS) circuit
Piezo pressure transmitter, installation in Ex zone
P+ / P− sleeves Ø 4...6 mm. OCT versions have 2 stainless steel (316L) tube connections for clamp ring fittings Ø 6 mm
0...100 Pa
Minimum measuring range is 5 % of full range (e. g. 25 Pa at ...500 Pa switch)
T90 / 5 s
< ± 1 % typically, max. ± 5 % of end value ±1 Pa
0,1...10 Pa (factory setting 2 Pa)
5 s
3...240 s (factory setting 120 s)
0...240 s (factory setting 0 s / Off)
Via menu. Short-circuit mechanically both tube connectors P+ / P− for the moment of zero point setting
Potential free switching contact – breaking / making contact, adjustable per menu
max. rating load: 0,5 A (30 VAC/DC) – 0,1 A (250 VAC) – 0,1 A (220 VDC); min. rating load: 10 mW / 0,1 V / 1 mA
–
6
10 × 10
3
SB 1.0
Pressure switch, 3 self-tapping screws 4,2 × 13 mm resp. in stainless steel (with ...CT and ...VA versions), short circuit tube
www.schischek.com
...-VA
...-OVA
E X P L O S I O N P R O O F
...-P-500
0...500 Pa
0,5...50 Pa (factory setting 10 Pa)
–
as above
Special solutions and accessories
...-CT
Types in aluminium housing with seawater resistant coating,
parts nickel-plated
...-OCT
Offshore version in aluminium housing with seawater resistant coating,
parts nickel-plated
...-VA
Types in stainless steel housing, parts nickel-plated
...-OVA
Offshore version in stainless steel housing, parts nickel-plated
MKR
Mounting bracket for round ducts up to Ø 600 mm
Kit 2
Flexible pressure tube, 2 m, inner Ø 6 mm, 2 connection nipples
Kit-S8-CBR 2 cable glands M16 × 1.5 mm, Ex-e, brass nickel-plated, for cable Ø 5...10 mm
Kit-Offs-GL-CBR 2 cable glands M20 × 1.5 mm, Ex-d, Ms-Ni, for armoured cables
Kit-PTC-CBR 2 connecting tubes for tube fittings Ø 6 mm, stainless steel 316 L
...-P-5000
0...5000 Pa
5...500 Pa (factory setting 100 Pa)
–
as above
ExBin-P_en
V02 – 18-Oct-2016
2 / 6