Cleaning and maintenance
Recurring testing
Risk of injury if personnel
WARNING
is not sufficiently qualified
Serious injuries and damage to property may occur
as a result.
e
Only allow trained and appropriately qualified
personnel to work on the Wallbox.
The following recurring tests are required by law:
Component
Wallbox
Wallbox
Vehicle cable, Wallbox
Electricity meter
NOTICE
Some of the recurring tests may be carried out by a
qualified electrician only g Fig. on page 43.
Information
−
The operator is responsible for the recurring
testing.
−
Contact and commission providers of calibration
tests in good time before the calibration expires.
−
See the
g Installation instructions
for detailed information on the required qualifi-
cation
Type of test
–
Visual inspection for any defects.
–
Check if operational.
Make repeated measurements and
carry out tests in accordance with
local regulations (e.g. DIN VDE
0105-100 for Germany)
Make repeated measurements and
carry out tests in accordance with
local regulations (e.g. DIN VDE
0701/0702 for Germany).
Check in accordance with the calibra-
tion law
Test interval
Daily / on every charging operation
Annually
Annually
Every 8 years from date of manufac-
ture
Cleaning and maintenance | EN
To be carried out by
User / operator
Skilled electrician
Skilled electrician
43