Keep the appliance in a cold and dry place out of
reach of ignition sources and flammable materials.
Pack the knife properly to avoid cutting injuries.
Putting the appliance into operation again
Remove the spark plug.
Pull the starter cable several times so that the combustion
chamber gets removed from the remaining oil.
Clean the contacts of the spark plug or fit a new one.
Refuel the tank. See the Fuel and oil section.
Start the engine as specified under "Cold engine starting".
Air filter servicing
An air filter that is dirty reduces the engine output due to
too low air supply to the carburettor.
A regular inspection is therefore necessary. The air filter
should be checked every 25 hours of operation and
cleaned if necessary. If the filter is too dusty, it should be
checked more often.
1.
Remove the air filter cap.
2.
Remove the filtration element.
3.
Clean the filtration element by tapping or blowing out.
4.
Assembly takes place in reverse order.
Never clean the air filter with petrol and flammable
solvents.
Spark plug servicing
Socket plug = 0.6 mm
Spark plug torque: 12 - 15 Nm.
Check the spark plug after 10 hours of operation for any
dirt and clean it with a copper wire brush if necessary. The
spark plug should then be serviced every 50 hours of
operation.
1.
Remove the socket plug by twisting.
2.
Remove the spark plug by the spark plug socket
wrench.
5.
Assembly takes place in reverse order.
Knives servicing
Sharpen or replace the rotational knife, star knife and
string cut-off knife if necessary.
Troubleshooting
The table shows potential failures, their possible cause
and removal options. However, if you are unable to
remove the problem, contact a professional to assist you.
Switch off and unplug the appliance before any
servicing and cleaning.
Symptom
Possible cause
Tank is empty
Spark plug is dirty
Functional switch
in "OFF" position.
Engine not
Carburettor
starting
Spark plug is wet
Spark plug cable is
defective
Choke adjusted
wrongly
Appliance
starting but
Air filter is dirty
without full
output
Carburettor
adjusted wrongly
Fuel mixture is
wrong
Engine smoking
excessively
Carburettor
adjusted wrongly
15
Remedy
Refuel the tank.
Clean or replace the
spark plug.
Put the switch to "ON"
position.
Clean the carburettor
or seek the customer
service centre.
Dry the spark plug.
Contact a
professional/service
centre.
Check the choke
adjusting.
Clean the air filter.
Contact a
professional/service
centre.
Use the right fuel
mixture.
Contact a
professional/service
centre.