Power supply
– For connection values refer to technical
specifications.
– The electrical connections must be
done by an electrician according to IEC
60364-1.
WARNING
The highest allowed net impedance at the
electrical connection point (refer to techni-
cal data) is not to be exceeded. In case of
confusion regarding the power impedance
present on your connection, please contact
your utilities provider.
DANGER
– Check whether the voltage indicated on
the type plate corresponds to the volt-
age of the socket.
– Unsuitable electrical extension cables
can be hazardous. Only use electrical
extension cables outdoors which have
been approved and labelled for this pur-
pose and have an adequate cable
cross-section:
1 - 10 m: 4 mm
10 - 30 m: 6 mm
60 Hz model
With this appliance model, the matching
mains plug must be installed onto the
mains connecting line by an electrician.
Water connection
According to applicable regula-
tions, the appliance must never be
used on the drinking water net
without a system separator. A suit-
able system separator by KÄRCHER or al-
ternatively a system separator according to
EN 12729 type BA must be used.
Water that was flowing through a system
separator is considered non-drinkable.
Always connect the system separator to
the water supply, never directly to the appli-
ance!
2
2
Quality requirements for water:
Parameter
pH value
electrical conductivity
Hydrocarbons
Chloride
Calcium
Total hardness
Iron
Manganese
Copper
Sulphate
Active chloride
free of bad odours
For connection values, see type plate/tech-
nical data.
 Use a fibre-reinforced hose (not includ-
ed in standard delivery).
Diameter should be minimum 1".
 Connect the hose to the water connec-
tion of the appliance.
 Connect the hose to the water tap.
Suck in water from vessel
A prepressure pump must be connected in
front of the appliance to suction water.
DANGER
Never suck in water from a drinking water
container.
DANGER
Never draw in fluids containing solvents or
undiluted acids and solvents! This includes
petrol, paint thinner and heating oil. The
spray mist thus generated is highly inflam-
mable, explosive and poisonous. Do not
use acetone, undiluted acids and solvents
as they are aggressive towards the materi-
als from which the appliance is made.
 Connect the water connection of the ap-
pliance to the prepressure pump (suita-
ble hose: 4.440-270.0).
 Remove air from appliance before oper-
ation.
– 4
EN
Value
6,5...9,5
max. 2000
µS/cm
< 0,01 mg/l
< 250 mg/l
< 200 mg/l
< 28 °dH
< 0,2 mg/l
< 0,05 mg/l
< 0,02 mg/l
< 240 mg/l
< 0,1 mg/l
17

Publicité

loading

Ce manuel est également adapté pour:

Hd 9/50-4 cage1.367-155.01.367-157.0