OPERATION
General
Use the following information and procedures to operate a
Hatco
Flav-R 2-Go
Pizza Locker System.
®
®
WARNING
Read all safety messages in the IMPORTANT SAFETY
INFORMATION section before operating this equipment.
CAUTION
BURN HAZARD: Some exterior surfaces on unit will get
hot. Avoid unnecessary contact with unit.
Startup
Use the following procedure to turn on the unit.
1. Move the Power I/O (on/off) switch to the I (on) position.
• The Power I/O (on/off) switch is located above the
operator's touchscreen controller.
• The touchscreen and heating elements (if enabled) will
energize.
• After the software loads, the Select Lockers screen or
Orders Ready screen will appear, depending on the
controller (operator or customer).
Red text indicates
locker is overtime.
White text indicates
time food is
in locker.
Description of Select Lockers Screen (operator)
CAUTION
BURN HAZARD: Some exterior surfaces on the unit will
get hot. Use caution when touching these areas.
2. For lockers with HEATED mode enabled: allow the heated
lockers 30 minutes to reach operating temperature.
• The factory setpoint temperature is 150°F.
3. Refer to the "Placing an Order" procedure to input
customer order information and place food into a locker.
Shutdown
1. Move the Power I/O (on/off) switch to the O (off) position
and allow the unit to cool completely.
2. Perform the "Daily Cleaning" procedure in the
MAINTENANCE section of this manual.
NOTE: If unit is shutdown with active orders, the orders will be
saved for when the unit is turned back on, but the timer
will be reset. To clear orders refer to the "Clear a Single
Order" procedure in this section.
Placing an Order (Operator Side)
Use the following procedure to place a completed and packaged
customer order into a locker for holding.
1. On the Select Lockers screen, touch the desired open
locker number(s).
• Up to three lockers can be selected if the food order will
not fit in one locker.
2. With the locker(s) selected, touch PLACE ORDER.
3. Type the name of the order and touch ENTER.
Locker in
HEATED
mode.
Order
Code
Locker is
disabled.
Error
Settings
10
English
Enter Name Screen