9
CAM interface
There is an electrically isolated, bi-directional interface available for communication with the CAM device�
en
Via two inputs and two outputs, 4 commands can be received from the extraction unit or 4 status informa-
tion can be sent to the CAM machine�
9.1
Pin assignment CAM interface (12, Fig. 1)
Type: RJ45
Pin
1
2
3
4
5
6
7
8
9.1.1
Outputs (Out1 / Out2)
The output signals are potential-free switch outputs, in an optocou-
pler, with a 150 Ohm series resistor�
Please see chapter 8, Technical Data, for the maximum pull-up volt-
age (U) and the maximum permissible switching current (I)�
The external pull-up resistor (R) must be set so that the maximum
permissible switching current ( I) is not exceeded�
9.1.2
Inputs (In1 / In2)
The input signals go to the optocoupler LEDs. See chapter 8, Technical Data, for the specified input volt-
ages of the two signal levels „low" / "high"�
9.2
Control commands / Status information
In 1
0 V (low)
24 V (high)
0 V (low)
24 V (high)
Out 1
24 V
0 V
24 V
0 V
Description
Out2- GND
Out2
Out1- GND
Out1
In2 - GND
In2 - 24 V
In1 - GND
In1 - 24 V
In 2
Commands
0 V (low)
Suction off (turbine off)
0 V (low)
Suction on (turbine on)
24 V (high)
Carry out cleaning
24 V (high)
No allocation
Out 2
Signal
24 V
Error
24 V
Cleaning active
0 V
Filter change
0 V
Suction ok
- 14 -