Maintenance
4.2.3
Chemicals
Some substances may be absorbed by the material of the facepiece body or
may possibly diffuse into it. Further information can be obtained from Dräger.
4.3
After use
WARNING
Do not doff the facepiece unless you are decontaminated and in a safe
environment.
1. Disconnect the lung demand valve:
Press button and simultaneously remove the lung demand valve from the
equipment connector.
2. Remove the facepiece:
Insert index finger behind the tabs on the neck straps and press the
adjusting clamps forwards with your thumbs while simultaneously pulling the
facepiece forward off your face over your head.
5
Maintenance
5.1
Recommended inspection and maintenance
intervals
The following details are manufacturer recommendations. In addition, comply
with the applicable national guidelines.
Type of work to be
Before
After
performed
use
use
Check by wearer
X
Visual inspection,
X
function and leak
test
Cleaning and disin-
X
fection
Replace exhalation
valve disc
96
Every
Every
Every
6 months
2 years
6 years
1)
X
2)
X
X
Instructions for use
|
Panorama Nova Use Instructions for NIOSH-approved full facepieces
Type of work to be
Before
After
performed
use
use
Replace speech dia-
phragm
1)
Interval may be anhanced to 2 years for air-tight packed facepieces.
2)
Valid for airtight packed facepiece, other facepieces every 6 months.
5.2
Cleaning and disinfecting
5.2.1
Cleaning and disinfecting
The facepiece must be cleaned after every use so that it is clean before it is
used by a different individual or, if individually assigned, as often as necessary
to keep in a sanitary condition. Facepieces that are issued to more than one
user must be cleaned before being worn by different individuals.
The facepiece must be disinfected after every use to keep it in a sanitary
condition. It is fully in the user's responsibility to make sure that the facepiece is
totally free of contaminants after this treatment. Never use a facepiece , that has
not been properly disinfected. In case of doubts dispose of the facepiece in
accordance with the local regulations and use a new one.
WARNING
The facepiece body must be thoroughly cleaned so that no residues from skin
care products remain on it.
Otherwise, the elasticity in the sealing range can be lost and the facepiece will
no longer fit correctly.
Non-observance of this warning can cause toxication ordeath.
CAUTION
Risk of damaging the materials!
Do not use any solvents (e.g. acetone, alcohol) or cleaning agents containing
abrasive particles for cleaning and disinfecting. Only apply the described
procedures and use the cleaning and disinfecting agents given. Other agents,
dosages and exposure times may damage the product.
Do not use a cloth to clean or dry the inside of facepieces with visors that are
marked "PC/CC". This may damage the coating. After drying, these facepieces
should be aired unpacked for at least one day under standard climatic
conditions according to DIN EN ISO 291, so that the coating can regenerate
and the optimum working life is achieved.
Every
Every
Every
6 months
2 years
6 years
X