en
|
Transport
4.6
During use
4.6.1
Low temperatures
Use anti-fog coated visors (PC/CC) or protect the inside of the visor against
fogging with "klar-pilot" gel.
4.6.2
High temperatures/alternating thermal stress
WARNING
Danger of poisoning
► Leave the danger zone as soon as any signs of damage become apparent,
e.g. bubbles in the visor.
The coating of visors marked PC/CC may dissolve in some places. The
facepiece remains usable until the end of the mission. Replace the visor after
use.
4.6.3
Chemicals
Some substances can be absorbed by the material of the mask body or may
even diffuse through it. Further information can be obtained from Dräger.
4.7
After use
4.7.1
Removing the respiratory filter or lung demand valve
● RA-type connector: Unscrew the respiratory filter or the lung demand
valve.
● PE-type connector: Unscrew the lung demand valve.
● ESA-type connector: Unscrew the respiratory filter or press the buttons on
the lung demand valve and, at the same time, pull the lung demand valve
out of the connector.
● P-type connector: Press the button (see figure A-1 on fold-out page) and,
at the same time, pull the lung demand valve out of the connector.
18
4.7.2
Removing the facepiece
CAUTION
► To prevent damage to it, do not pull the mask off your head by pulling on the
connector.
Removing the full face mask
1. Push the adjuster buckles of the neck straps forward with your thumb and
loosen the straps (see figure E on fold-out page).
2. Pull the full face mask away from your face and over your head.
Removing the mask/helmet combination with Supra adapter
3. Pull both mask/helmet adapters evenly to the rear, then flip them away from
the helmet.
4. Remove the facepiece.
4.7.3
Maintenance work and maintenance intervals
For information on maintenance work and maintenance intervals, refer to
technical manual 9300782 at www.draeger.com/ifu.
5
Transport
Transport facepiece in a carrying box or mask bag.
6
Storage
● Loosen the head harness as far as possible.
● Make sure that the facepiece is dry.
● Pack the full face mask in its bag or carrying box.
● Store the full face mask in a dry, dust-free place where it cannot become
deformed.
● Protect from direct sunlight and thermal radiation.
● Storage temperature: -15 °C to +25 °C
● Observe ISO 2230 and national regulations concerning the storage,
maintenance and cleaning of rubber products.
Instructions for use
|
Panorama Nova

Publicité

loading