English
5. Carefully lower the condensing unit followed by the hot/
cold shelf into the countertop cutout. This step requires
two or more people.
• The condensing unit must go into the cutout first and be
fastened to a level, stable surface within 4' (1219 mm)
of the connections on the bottom of the hot/cold shelf.
Refer to the SPECIFICATIONS section for installation
dimensions.
• The hot/cold shelf rests on top of the four leveling
bolts, which are part of the mounting bracket assembly
installed at each corner of the countertop cutout.
6. Adjust the leveling bolts underneath each corner of the unit
so that the shelf is flush or slightly below the countertop
surface.
7. Tighten the lock nut on each leveling bolt to secure the
position.
8. Apply a bead of NSF-approved silicone sealant in the gap
between the countertop and the hot/cold shelf. To apply a
clean, consistent sealant bead:
a. Make sure the shelf is centered in the countertop cutout.
b. Install masking tape on each side of the gap to define
the edge of the sealant.
c. Carefully apply sealant into the gap.
d. Quickly smooth the sealant surface.
e. Carefully remove the masking tape before the sealant
dries.
NOTE: The silicone sealant must be rated for use at temperatures
between -10°F (-23°C) and 250°F (121°C).
CAUTION
DO NOT tip unit/mounting surface after final installation.
Unit is free-floating and could fall out if tipped—for
permanent, horizontal installations only.
9. Install the control panel in the desired location, if installing
remotely.
• The control panel can be installed remotely within
4' (1219 mm) of the condensing unit. Refer to the
"Installing the Control Panel Remotely" procedure in this
section.
NOTE: On export units only, the control box can be installed
within 8-1/2' (2591 mm) of the condensing unit with an
optional 8-1/2' (2591 mm) control cable.
10. Clean the hot/cold shelf surface thoroughly in preparation
for initial operation. Refer to the MAINTENANCE section
for proper cleaning procedures.
11. Plug the unit into a properly grounded electrical receptacle
of the correct voltage, size, and plug configuration. See the
SPECIFICATIONS section for details.
HCSM-0424
Installing the Remote Control Box
Use the following procedure to install the remote control box.
Control box must be mounted in a vertical surface.
Mounting control box in a horizontal surface may result in
the collection of liquids and lead to electric shock.
1. Remove the six trim cover screws from the control box,
and remove the trim cover.
2. Position the control box into the cutout opening through the
backside.
3. Fasten the control box to the vertical surface using four
screws (not supplied).
4. Reinstall the trim cover on the control box and secure
in position using the six trim cover screws. Seal the trim
cover to the mounting surface with silicone adhesive.
13-1/16"
(332 mm)
13-3/8"
(340 mm)
Remote Control Box Cutout Dimensions
NOTE: Make sure the width of the control box cutout does not
exceed the above dimension.
15
INSTALLATION
WARNING
5-5/8"
(143 mm)
1-1/16"
(27 mm)
3-1/2"
(89 mm)