SPECIFICATIONS
Plug Configuration
Units are supplied from the factory with an electrical cord and
plug installed. Plugs are supplied according to the application.
ELECTRIC SHOCK HAZARD: Plug unit into a properly
grounded electrical receptacle of the correct voltage,
size, and plug configuration. If plug and receptacle do not
match, contact a qualified electrician to determine and
install proper voltage and size electrical receptacle.
NOTE: Receptacle not supplied by Hatco.
Refrigerant Information
All Hatco Built-In Hot/Cold Shelves use R-513A refrigerant in
the condenser unit.
Operating Specifications
Discharge
Suction
Pressure
Pressure
115 to 125 psig
6 to 9 psig
(7.9 to 8.6 bar)
(0.4 to 0.6 bar)
NOTE: The Operating Specifications are accurate for units in an ambient
air temperature of 75°F (24°C).
Electrical Rating Chart — HCSSB Models
Compressor
Model
Size
1/5 hp (60 Hz)
HCSSB-2418
1/3 hp (50 Hz)
1/5 hp (60 Hz)
HCSSB-3018
1/3 hp (50 Hz)
1/5 hp (60 Hz)
HCSSB-3618
1/3 hp (50 Hz)
1/3 hp (60 Hz)
HCSSB-4818
3/8 hp (50 Hz)
The shaded areas contain electrical information for Export models only.
NOTE: Shipping weight includes packaging and is estimated.
WARNING
Superheat
4° to 10°F
(2.2° to 5.6°C)
Volts
120 V
220/230/240 V 1089/1190/1296 W
120 V
220/230/240 V 1089/1190/1296 W
120 V
220/230/240 V 1089/1190/1296 W
120 V
220/230/240 V
826/904/984 W
NEMA 5-15P
CEE 7/7 Schuko
NOTE: The specification labels are located on the side of the
control box. See the label for the serial number and
verification of unit electrical information.
Subcooling
5° to 10°F
(2.8° to 5.6°C)
Hot Side
Watts
Watts
300 W
405 W
371/405/441 W
300 W
510 W
467/510/555 W
300 W
610 W
558/610/664 W
450 W
815 W
746/815/887 W
6
Plug Configuration
Rated
Plug
Amps
Configuration
3.8 A
NEMA 5-15P
CEE 7/7,
5.0/5.2/5.4 A
BS-1363, AS 3112
4.3 A
NEMA 5-15P
CEE 7/7,
5.0/5.2/5.4 A
BS-1363, AS 3112
5.1 A
NEMA 5-15P
CEE 7/7,
5.0/5.2/5.4 A
BS-1363, AS 3112
6.8 A
NEMA 5-15P
CEE 7/7,
3.8/3.9/4.1 A
BS-1363, AS 3112
English
BS-1363
AS 3112
Shipping
Weight
120 lbs.
(54 kg)
120 lbs.
(54 kg)
150 lbs.
(68 kg)
150 lbs.
(68 kg)
170 lbs.
(77 kg)
170 lbs.
(77 kg)
195 lbs.
(88 kg)
195 lbs.
(88 kg)