INSTALLATION
Installing a Bottom Mounted Unit
(HCSSB and HCSSBF Series)
NOTICE
Use caution and avoid hitting condensing unit hoses/lines
when installing unit. Damage caused during installation is
not covered under warranty.
1. Remove the mounting
bracket assembly from
each corner of the hot/cold
shelf. To remove:
a. Remove
the
shipping screws and
washers that attach
each mounting bracket
assembly to the bottom
of the unit.
b. Carefully lift the hot/cold
shelf above the wooden shipping frame, and rotate it far
enough to allow the unit to be set back down on top of
the frame (the mounting brackets will stay on the frame
or fall out the bottom). Make sure the flexible tubes from
the condensing unit are not strained or damaged. This
step requires two or more people, depending on the
unit.
c. Remove the mounting bracket assemblies from the
frame, if necessary.
Gasket
Lock Nut
Leveling Bolt
Inside surface of
Inside surface of
mounting bracket
mounting bracket
assembly flush with
assembly flush with
inside of cutout.
inside of cutout.
Bottom
of unit.
two
Mounting
Bracket
Assembly
Washer
Shipping
Screw
Condenser
Coils
Installing a HCSSBF Series Hot/Cold Shelf
2. On each mounting bracket
assembly,
remove
shipping screws and the
triangular shipping bracket
that was used to attach the
mounting bracket assembly
to the bottom of the hot/cold
shelf and discard.
3. Attach a mounting bracket
assembly to the underside
of the prepared countertop
at each corner of the cutout.
a. Align the U-shaped mounting holes on the mounting
bracket with the two pre-drilled mounting holes on the
underside of the countertop. The inside surface of the
mounting bracket should be vertically flush with the inner
surface of the countertop cutout.
b. Insert appropriate fasteners through the mounting
bracket and into appropriate anchoring devices in the
mounting holes on the underside of the countertop.
Tighten securely.
4. Install the included self-adhesive gasket around the inner,
vertical surface of the countertop cutout.
• The gasket should be positioned 1/4" (6 mm) below the
top surface of the countertop.
NOTE: If the self-adhesive gasket is not available, provide a
caulk backing around the inner, vertical surface of the
countertop cutout 1/4ʺ (6 mm) below the top surface
of the countertop. This will prevent the silicone sealant
applied later in this procedure from falling through the
gap between the countertop and the hot/cold shelf.
14
English
Shipping
Bracket
the
Shipping
Screw
Countertop
Cutout
HCSM-0424