PH 2
19 mm
24 mm
440 mm
200 ± 2 mm
Required tools:
- Pliers
- Wrench, width 19 mm
- Wrench, width 24 mm
- Pozidrive screwdriver PH 2
- Cutting knife
Tubes for cool and hot water:
The blue and red connection tubes are supplied
unassembled with the water conditioning unit.
The tubes must not be kinked or shortened, as
this will prevent the system from functioning
properly!
The distance between the mixer tap and water
conditioning unit should not exceed 80 cm.
Hoses, tubes and lines must not be strained.
For repairs or cleaning purposes, it must be
possible to pull the water conditioning unit
forward, so there should be some tube reserve
in the base cabinet.
Water conditioning unit dimensions:
Height: 440 mm
Width: 202 ± 2 mm
Housing depth: 495 mm
Depth incl. spacer at rear: 530 mm
When positioning the system in the base
cabinet, make sure that there are no corner
valves, socket outlets or other installations
behind the unit.
Transport:
When transporting the system, make sure
that the CO
cylinder has been removed
2
and the system is emptied.
6 hours waiting time:
After the system has been transported to its
installation site, it must be left to settle for
6 hours. The installation can be prepared but
the power supply for the water conditioning
unit may only be connected after a waiting
time of 6 hours.