6.3

Electrical components

7 TROUBLESHOOTING

7.1 Alarm management

Alarms are indicated by an acoustic signal (if activated) and a message on the control panel.
In case of an alarm the shutdown procedure is automatically activated. Cancel the signal by pressing button P3 on
the remote control or the emergency panel and wait for the insert to reach OFF status. Eliminate the cause and
restart the insert according to the normal procedure described in this manual. Listed below are the alarms that can
appear on the control panel, with the causes and cures:
Signaling
Occurs in case of a power
AL 1
failure during the operation
POWER
phase
FAILURE
AL 2
Occurs in case of a fume
FUME
temperature detection probe
fault
PROBE
AL 3
Occurs if the probe detects a
HOT FUMES
high fume temperature
AL 4
Occurs when the fume
exhaust fan is faulty
FAN FAIL
AL 5
Pellets do not ignite in the
NO IGNITION
lighting phase
AL 6
The flame goes out during the
operation phases
NO PELLETS
ALARMS - MESSAGES
Fault
Electrical system power failure
in the room where the insert is
installed
- Probe fault
- The probe is disconnected
from the board
- Overheating due to use of
the insert for too long
- The tangential fan is faulty or
not powered
- Excessive pellet load
- The fume fan is blocked
- The speed control sensor is
faulty
- No power to the fume fan
- The pellet hopper is empty.
- The heater is faulty, dirty or
incorrectly positioned.
- Incorrect pellet load setting.
- The pellet hopper is empty
- The pellet feed gearmotor is
faulty or not powered
Possible causes
56
Key:
1- Electronic board L023
2-Safety thermostat
3- Power supply connector
4- Safety microswitch
5- Fume probe
6- Gearmotor
7- Fume extractor
8- Centrifugal fan
9- Air flow meter
10-Control and safety vacuum switch
11-Control panel model L026
Cures
- Turn the insert OFF by
pressing button P4 and repeat
the lighting procedure
- Other reinstatement
operations must be carried
out by a service center
Reinstatement operations
must be carried out by a
service center
- Wait for the insert to cool and
repeat the lighting procedure
- Other reinstatement
operations must be carried out
by a service center
Reinstatement operations
must be carried out by a
service center
- Check the presence of
pellets in the hopper.
- Repeat the lighting
procedure
- Other reinstatement
operations must be carried
out by a service center
- Check the presence of
pellets in the hopper
- Repeat the lighting
procedure
- Other reinstatement
operations must be carried
out by a service center
TOPFIRE 70 SLIM