If the compartment is not accessible, proceed as follows:
1 - remove the pullout part of the insert from the guides and the fixed base by undoing the 9 guide-fixing screws
each side, after pulling it out completely;
2 - fix the base in the reference compartment with 8 anchors, making sure it is flat-horizontal and perpendicular to
the outer wall;
3 - make connections to the flue A and possible combustion air inlet B (available on request) without forcing the
connection parts on the base;
4 - make the electrical connection and/or ensure that the electric cable is run safely to the external outlet;
5 - after pulling out the telescopic guides from the base, refit the monoblock on them, carrying out the procedure of
step 1 in reverse order;
6 - check the sliding of the pullout part, locking of the latch and operation of the safety
microswitch for the insert's power supply;
9 screws LH
9 screws RH
Electrical
connection
The insert has a remote control with display and incorporated ambient probe for measuring the temperature in the
context of the room.
For measuring away from the unit, the installation of a room chronothermostat/thermostat is recommended.
- Installation and assembly must be done by qualified and/or authorized personnel.
- The insert cannot be installed in bedrooms, bathrooms and in general in rooms where
another heating unit is already installed without an independent air inflow.
It is advisable to provide suitable fire-prevention devices for any eventuality.
-
- Do not install the insert in places with an explosive atmosphere.

2.3 Combustion air inlet

In the room where the insert is installed a quantity of air must flow at least equal to that required for combustion; for
this reason must be guaranteed a flow of air, clean and free of pollutants, to satisfy a regular combustion at
maximum power without any hindrance or obstruction of the passage section; must also be drawn in from the
condition that in the vicinity of the insert is practiced an air intake communicating with the outside wall of the free
surface of at least 100 cm ² suitably protected externally by a protection grid to prevent obstructions.
B
The combustion air is drawn through a
PROTECTION GRID complete internal
network located in the proximity of the
installation compartment of the insert
(maximum distance of 1 m. From the
suction pipe). This component is not
present in the air intake kit optional.