Set up the electricity supply line to arrive near the
appliance for the connection of the power cable.

6.4 Combustion air

The appliance, during its operation, requires
combustion air.
The flow of combustion air must come from the
installation room or suitable adjacent rooms (Fig.
16).
extraction of combustion air in the room
Create the air inlet on the wall (Fig. 16 - pa = Air
Inlet), and allow the appliance to take air into the
room.
004778640 - 10/02/2021
Pi
X
Fig. 15
ITALIANO
If the rear wall of the appliance is an external
wall, create a hole for the intake of combustion
air at a height off the ground of about 20-30 cm,
in accordance with the dimensional instructions
reported in the section "4.3 Technical features"
on page 67.
A non-closable permanent aeration grid must
be placed externally; in areas that are particularly
windy and exposed to weathering, provide rain
and wind protection.
Ensure that the air intake is positioned so that it
won't be accidentally obstructed.
If it is impossible to create an external air intake
in the wall behind the appliance (non-perimeter
wall), a hole must be made in an external wall of
the room where the appliance is positioned.