Selecting functions
1 ON - Automatic closing - The automatic closing timer activates upon upon full opening. The preset time is adjustabel, but
it's in any case subject to any safety device intervention and does not activated after a Total Stop or in case of power
failure (1 OFF - deactivated);
2 OFF - APre-Closes with button (2-7) and/or transmitter (requires radio frequency card).
2 ON - Solo apre with button (2-7) and/or transmitter (requires radio frequency card).
3 ON - 24 V output on contact (10-E) barrier arm in movement and in closed position;
3 OFF- 24 V output on contact (10-E) barrier arm in movement;
4 ON - Maintained action - the barrier works by keeping the button pressed, a button 2-3 for opening, a button 2-7 for
closing (position jumper n. 14 as shown in fi gure 16. 14 come in fi gura A pagina 16).
5 ON - Pre-fl ashing when opening and closing - After either an opening or closing command, the fl ashing light and/or
luminous cord conencted on [10-E], fl ash/es for 5 secodns before cycle start.
6 ON - Obstacle detection - With motor stopped (barrier arm closed, open or after a total stop command), prevents any
manouvre if the safety davices (i.e. photocells) detect an obstacle..
7 ON - Slave function - To be activated when having two combined barriers (see Connecting two combined barriers
paragraph;
8 OFF - Immediate closing - Immediately closes the barrier after vehicle has passed within the oeprating range of the safety
devices. Insert safety device on [2-C5]; if unused, set DIP switch to ON.
9 OFF - Total stop - Barrier arm stop and exlusion of automatic closing; to resume movement pres command button or trasmitter
key. Connect button on [1-2]; if unused, set DIP switch to ON.
10 ON - Braking action - Increase braking action of the closing barrier arm (10 OFF - deactivated)
Adjustments
LIST OF ADJUSTMENT TRIMMERS:
- A.C.T.
Adjusts opening waiting time. Once this time has elapsed, the barrier closes automatically. The waiting time can be
adjusted to between 1 and 120 seconds..
- SENS
Adustes the amperometric sensitivity which controls the force developed by the motor during movement; if the force
exceeds the adjusted level, the system intervenes and inverts the direction of travel.
Default setting
ON
OFF