Power source and accessories
Terminals for powering accessories:
- for 24 V AC at normal operation;
- when emergency batteries are operating;
Overall allowed power: 40 W
Power source 230 V AC, Frequency 50 / 60 50/60 Hz
Eyelet terminal with screw and wa-
sher for ground connection
Command devices
NC contact stop button) - Excludes automatic closing. To resume movement pres command
button or trasmitter key.
if unused, set Dip switch 9 to ON.
( NO contact opening button)
Button for barrier opening and closing commands NO
contact - the barrier opens or invert movement depending
on what is selected on Dip-switch 2.
Check position of jumper (n 14, page 16) as shown in
fi gure.
(NO contact closing button) this is obligatory with
Maintained Action function.
Position jumper as shown.
Immediate Closing (NC) Contact
Immediately closes the barrier after vehicle has passed
within the oeprating range of the safety devices.
if unused, set Dip switch 8 to ON.
}
}
DELTA S Photocells
RX
TX