User Manual
Operating Instructions
Fault: Blockage in the downstream progressive system, continuation
Cause:
Metering device blocked
Fault: Differing lubricant amounts at the lubrication points
Cause:
Lubricant metering not correct
Respective valve body has been assembled without clamp-
ing ring
Setting of the pause t ime or lubricating time incorrect
Fault: Over- or underlubrication of the l ubrication points
Cause:
Setting of the lubricating time or pause time incorrect
Tab. 1
Troubleshooting, continuation
Page 20 of 24
LINCOLN GmbH • Postfach 1263 • D-69183 Walldorf • Tel +49 (6227) 33-0 • Fax +49 (6227) 33-259
Troubleshooting, continuation
Correction:
Replace the metering device or clean it in accordance with
the following procedure:
Remove all tube fit tings.
Unscrew t he piston closure plugs.
If possible, try to eject the piston using a smooth drift
(Ø smaller than 6 mm; 0.24 in.).
IMPORTANT
he pistons are precision-f itted into the
holes. Mark the pistons with regard to their
installation position and direction after they
have been removed. They must not be
6001a 02
exchanged.
Thoroughly clean the metering device bodies in f at-
dissolving washing agent, blow t hem through with com-
pressed air.
Press f ree the slant ducts (Ø 1.5 mm; 0.59 in.) at the
thread ends of the pist on holes using a pin.
Clean the met ering devices again and blow them through.
Reassemble the metering devices.
Replace the copper washers.
Before the tube fittings are reassembled, the metering
devices should be pumped with oil several cycles by
means of a manual pump. Check that the pressure in the
metering device does not exceed 25 bar (362.8 psi).
If the pressure is higher, replace the metering device.
Correction:
Check the lubricant metering acc. to the lubrication chart
Remove the valve body and install a clamping ring.
Check the time set ting. Refer to the corresponding setting
in the respective "Operating Instructions".
Correction:
Check the time set ting at the printed circuit boards. Refer
to the corresponding setting in the respective "Operating
Instructions".
2.2EN-20001-I11