Lubricant Distribution within the Metering Device, continuation
Fig. 19
Phase 3
Fig. 20
Phase 4
Fig. 21
Phase 5
LINCOLN GmbH • Postfach 1263 • D-69183 Walldorf • Tel +49 (6227) 33-0 • Fax +49 (6227) 33-259
Operation, continuation
Phase 3
Once piston B has reached its left-hand final position, the
junction channel to the right -hand end of piston A is
opened.
The lubricant, which flows from above (white arrow)
moves piston C (black arrow) to the left, causing the lubri-
cant quantity ahead of the left-hand end of piston C to be
dispensed to outlet 5 (dashed arrow).
2009a9 5
Phase 4
The channel to the right-hand end of piston D is now open
(black arrow).
The lubricant which is f ed from above (white arrow)
moves piston D to t he left, causing the lubricant quantity
ahead of the left-hand end of piston D to be dispensed out
of the metering device via outlet 3 (dashed arrow).
2010a9 5
Phase 5
In phase 4, piston D had opened the junction channel t o
the left-hand end of piston A.
The lubricant flowing in (white arrow) moves piston A to
the right (black arrow), causing the lubricant quantity to be
dispensed to outlet 1(dashed arrow).
In the subsequent distribution sequence, pistons B - D are
moved from the left to the right one after the other.
A complete distribution sequence is finished and a new
cycle can begin.
2011a9 5
2.2EN-20001-I11
Lubricant under pump pressure
Lubricant under delivery pressure of the piston
Lubricant, pressureless
Lubricant under pump pressure
Lubricant under delivery pressure of the piston
Lubricant, pressureless
Lubricant under pump pressure
Lubricant under delivery pressure of the piston
Lubricant, pressureless