Appropriate Use

Use the SSV and SSV M lubricant metering devices only for
dispensing lubricants in centralized lubrication systems.
Suitable Lubricants
The progressive metering devices model SSV can be used
for dispensing
- mineral oils of at least 40 mm
- greases up to t he penetration class NLGI 2
IMPORTANT
It must nevertheless be ensured that the
oils or greases used do not alter their con-
sistency significantly in the course of time or
6001 a02
under the influence of temperature or
pressure.

General Safety Instructions

The progressive centralized lubricat ion system connected
to t he Quicklub pump model 203 must always be secured
with a pressure relief valve.
Lincoln SSV and SSV M lubricant metering devices are
state of the art.
Incorrect use may result in bearing damage caused by
poor or over-lubrication.
Each outlet which will be used must be equipped with a
check valve.
In the case of the metering devices model SSV 6 - 12
the outlets 1 and/or 2 must never be closed.
Unauthorized modifications or changes to an installed
system are not admissible. Any modification must be
subject t o prior consultation with the manufacturer of the
lubrication system.
Use only original Lincoln spare parts (see Parts Catalogue)
or the parts approved by Lincoln.
Regulations for Prevention of Accidents
Adhere to the regulations for prevention of accidents which are
effective in the country where the system is to be used.
CAU TION!
Danger of injury in the case of serious
corrosion of metering device surfaces:
An increasing corrosion of the surfaces will
cause the balls pressed in to lose their hold.
Under pressure, they may suddenly burst
1013A94
out and cause injuries.
For applications in corrosive environments,
use metering devices in stainless steel
version only.
LINCOLN GmbH • Postfach 1263 • D-69183 Walldorf • Tel +49 (6227) 33-0 • Fax +49 (6227) 33-259

Safety Instructions

2
/s (cST) or
Operation, Repair and Maintenance
Authorized and inst ructed personnel who are familiar with the
centralized lubrication systems should only perform repair.
Installation
Install the metering devices at a suitable location in ac-
cordance with t he lubrication diagram.
It is recommended that the metering devices be installed in
such a way that the outlets are not close to the chassis or
the attaching plate. This will facilitate troubleshooting in the
case the system is blocked.
The main metering devices with indicator pin must be
installed in such a way that the indicator pin is easily visible.
When the push-in type fi ttings are used, note the follow-
ing:
For the metering device inl et use only push-in type
fittings (R 1/8) with reinforced collar and sealing ring.
For the outlet tube fittings of the SSV divider valve
(M 10x1) depending on the design of the lubricant line, f or
example
- high-pressure plastic hose (Ø 4.1 x 2.3) use valve bodies
with reinforced collar only, or,
- pressure plastic t ube (Ø 6 x 1.5) use valve bodies with
knurled collar only
For the outlet fittings of the SSV M divider divider valve
(M 8x1) pressure plastic tube (Ø 4 x 1) use valve bodies
with knurled collar only.
NOTE
In the case of construction machines or
agricultural machines use high pressure
plast ic hoses for the lubricant feet lines. In
6 001a02
such cases the outlet fittings of the sec-
ondary metering devices and the connec-
tion fittings to the lubricant points must
have a reinforced collet.
Use only the main and feed lines specified by Lincoln and
adhere to the specified syst em pressures.