10 Troubleshooting

10 Troubleshooting
DANGER
Risk of injury and device damage when handled by unauthorized persons
Improper repair work and modifications to the product may lead to serious injuries and damage to the device.
The product warranty will be rendered invalid if work is carried out on the product by unauthorized persons.
• Only qualified personnel are permitted to perform work on the device or system.
CAUTION
• Before performing any maintenance and cleaning work, suitable safety measures must be taken.
• Maintenance and cleaning work on the fume extraction system may only be carried out in areas with locally filtered
forced ventilation.
• Check and wear your personal protective equipment.
• Personal protective equipment consists of protective clothing, safety goggles, a class P3 respiratory mask, protective
gloves and safety shoes.
Note the attached document regarding the warranty. In the event of questions and/or problems, contact your retailer or the
manufacturer.
Fault
Unit is not ready for operation
Dust emission during dedusting
Error message for 0 / Error
LED: 8 short flashes
Error message for 0 / Error
LED: 3 short, 1 long, 4 short
flashes
Tab. 10
Troubleshooting
EN - 24
Cause
• Device component defective • Have it checked and replaced
• Extraction system defective
• Carbon brushes defective
• Fume extraction system
cannot be switched on
• Reduced extraction capacity • Clean the filter/empty the filter housing
• Exhaust air filter dirty
• Motor runtime > 8 hours
• Overheating > 60 °C
Troubleshooting
• Have it checked and replaced
• Have it checked and replaced
• Switch off the power to the system
Check motor protective switch
 9.2 Filter dedusting on page EN-18
 9.3 Emptying the filter housing on page EN-19
• Switch off the power to the system
Replace filter
 9.4 Changing the filter on page EN-20
• Check suction hose for cross-section reduction and
replace as needed
• Check suction hose for damage and clogging
• Replace exhaust air filter
 9.4.3 Replace the exhaust air filter on
page EN-22
• Switch off the power to the system
• Switch off the power to the system and let it cool
down