6 Commissioning
1 Connect the torch system (4), hose, and rubber connector to the fume extraction system (1).
2 Plug in the power plug.
3 Switch on the fume extraction system on the control panel with the I / Power button.
 Fig. 3 Control elements on page EN-10
NOTICE
• An external current clamp can be added on and is available as an accessory.
 6.3 Current clamp (optional) on page EN-13

6.2.1 Automatic starting

The automatic starting function allows the FEC to be automatically switched on when the welding process starts.Once the
welding process begins, the FEC receives a signal and automatically starts the fume extraction process.
1
6
1
Control panel
2
A / Auto button
Fig. 5
Automatic starting
1 Lay the ground cable (4) in the integrated automatic Start-Stop system (6).
2 Connect the ground cable (4) on one end to the power source and on the other end to the welding table, for example.
3 Press the A / Auto button (2) on the control panel (1).
 5.1 Control elements on page EN-10
The FEC starts automatically when the welding process is started.
EN - 12
3
Motor protective switch
4
Ground cable
2
3
4
5
5
Power cable connector
6
Integrated automatic Start-Stop system