Specific Safety Instructions En - Abicor Binzel FEC 115 V Mode D'emploi

Dispositif d'aspiration
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

FEC
CAUTION
Describes a potentially harmful situation. If not avoided, this may result in slight or minor injuries.
NOTICE
Describes the risk of impairing work results or potential material damage to the equipment.
2.5 Specific safety instructions
DANGER
Danger of explosion due to use of welding spray
During operation, please observe the following:
• Observe the hazard warnings and safety instructions in the Safety Data Sheet for the welding spray to be used.
• Switch off the fume extraction system before spraying the workpieces with welding spray.
• Do not allow the spray mist to be drawn into the fume extraction system by suction. In a hot system, this may lead to the
formation of flammable/explosive vapor-air mixtures.
WARNING
Health risk caused by harmful dust
Observe the following before and during operation:
• The fume extraction system contains harmful dust as of the first use.
• Only qualified personnel are permitted to perform work on the device or system.
• Check and wear your personal protective equipment.
• The fume extraction system may not be operated without the filter system.
• The fume extraction system may not be operated with an open dust collecting drawer.
• During operation and fume extraction, the complete fume extraction system must be kept closed.
NOTICE
• Make sure that the extraction hose is not damaged by being driven over, crushed, torn or similar.
• The fume extraction system must only be used for extracting and separating welding fume.
• Do not allow liquids, aggressive gases, inflammable media or glowing particles (smouldering nests or similar) to be
drawn in.
• Do not use or store the fume extraction system outdoors under humid conditions.
• Use of the fume extraction system when welding oil-contaminated metals is not permitted. Risk of fire!
• The 115 V // 50 Hz / 60 Hz or 230 V / 50 Hz power supply must be protected by a 16 A fuse on the mains side.
• If it is necessary to replace power cords or device connecting cables, only models indicated by the manufacturer may
be used.
• Make sure that the extraction hose is not damaged by being driven over, crushed, torn or similar.
• When using the welding fume filter, the volume flow that is led back to the work area may not exceed 50 % of the
supply air of the installation area. In the event of free room ventilation, the supply air flow corresponds to one room
volume per hour. This corresponds to a ventilation rate of 1/h.
Supply air flow [m³/h] = room volume [m³]
Example: When using an ABICOR BINZEL welding fume filter with a rated volume flow of 230 m³/h, the same
quantity of fresh air must be supplied. With natural ventilation, this is the case if the work area volume is at least 200 m³
(e.g.: surface of 58 m² multiplied by room height of 3.5 m).
BAL.0533.0 • 2019-11-15
ventilation rate [1/h]
*