6 Commissioning
6.4 Connector for separate exhaust air hose
1
Mounting screws (4 pieces)
Fig. 8
Separate exhaust air hose
1 Loosen the mounting screws (1).
2 Dismantle the air exhaust louver (2).
3 Connect the exhaust air hose (3) to the fume extraction system.
6.5 Establishing the electrical connection
 13.1 Circuit diagram on page EN-26
WARNING
Electric shock
Dangerous voltage due to defective cables.
• Check all live cables and connections for proper installation and damage.
• Replace any damaged, deformed, or worn parts.
NOTICE
• Before an electrical connection between the product and the power supply is established, check that the operating
voltage specified on the nameplate matches the actual voltage.
EN - 14
3
2
Air exhaust louver
1
2
3
Exhaust air hose
BAL.0533.0 • 2019-11-15