Faults
Use only MESTO spare parts and accessories (→ Fig. on page 2).
Fault
No pressure builds up in
the device
Liquid flows out of the
pump
No tank pressure indica-
tion on the piston pressure
gauge,
Safety valves blow off too
early.
The nozzle does not spray
even though pressure is
present
The shut-off valve does not
close.
Liquid emerges without the
lever being activated
Contact address for additional information → see title page.
AUS
USA
Cause
The pump is not screwed
on tightly.
O-ring [13] on the pump is
faulty. (Fig. 16)
Diaphragm [14] is defecti-
ve. (Fig. 16)
Valve disc [18] dirty of
defective. (Fig. 21)
Piston pressure gauge [10]
is defective
Nozzle [16] (Fig. 18) or
/ and filter [17] (Fig. 19)
clogged.
Discharge filter [6] (Fig.
20) blocked.
O-ring [19] of the pressure
bolt [20] is not greased /
lubricated. (Fig. 22)
Defective pressure bolt
[20] or
O-ring [19]. (Fig. 22)
18
NZ
CDN
Remedy
Screw the pump on tightly.
Replace the O-ring.
Replace the diaphragm.
Clean or replace the valve disc.
Have the piston pressure gauge
repaired (3237P).
Replace the piston pressure
gauge (3278P).
Clean the nozzle or / and filter.
Clean discharge filter.
Grease the O-ring of the pressu-
re bolt (dismantle or assemble
the pump → section „Care and
maintenance")
Replace the pressure bolt or
O-ring.