Sealing the glass
A tube of silicone sealant is supplied with the fireplace for application to all glass-to-glass connections on both sides
of the glass . The purpose of the silicone is to create a gasket, not to "glue" the glass panels together .
Glass Seal Assembly Diagram
TOP VIEW
Firebox
back wall
Side glass
panel
Front glass
panel
Front glass panel is
placed in front of the
side panel(s)
Silicone sealant is
applied to close
the distance
between glass
panels
•
When placing glass panels, ensure that the glass
is fully in place and that the silicone fills the
space between the glass panels . Place the front
or center panel in place first and then slide the
side panel into place so that the silicone edge
touches the glass edge .
•
After new silicone is applied, cure time is 24
hours before operation of the fireplace .
•
If silicone needs to be reapplied, high-
temperature RTV clear silicone, rated for
sustained exposure to 500 °F / 260 °C or higher
is required (Rutland 500ºF RTV High Heat Clear
Silicone Sealant is recommended .)
•
Re-apply high-temperature RTV clear silicone
only if the original silicone is damaged .
•
Do not use silicone to seal the glass after it is in
place .
•
Always use appropriate materials and cleaning
agents to clean glass .
64