2.
If the motor still does not start, check the motor' s carbon brushes. Replace
with new carbon brushes if they are worn down.
3.
Connect this tool with a fuse or circuit breaker. Using the wrong size fuse can
damage the motor. Fuses may 'blow' or circuit breakers may trip frequently if:
a.
Motor is overloaded. Overloading can occur if you feed the material
to the saw too rapidly or start/stop too many times in a short period.
b.
Voltage not more than 10% above or below the nameplate voltage can
handle normal loads. For heavy loads, the voltage may drop too low
for the motor to operate. This can be caused by a small gauge wire in
the supply circuit or an overly long supply circuit wire. Always check
the connections, the load and the supply circuit whenever motor
does not work well.
VIBRATION PRECAUTIONS
1.
This tool vibrates during use. Repeated or long-term exposure to vibration
may cause temporary or permanent physical injury. Take frequent breaks
when using the tool.
2.
If you feel any medical symptoms related to vibrations (such as tingling,
numbness, and white or blue fingers), seek medical attention as soon
as possible.
3.
Wear suitable gloves to reduce the effects of vibration.
4.
DO NOT use this tool before consulting a physician if one of the
following applies:
a.
Pregnant
b.
Impaired blood circulation to the hands
c.
Past hand injuries
d.
Nervous system disorders
e.
Diabetes
f.
Raynaud's Disease
UNPACKING
WARNING! Do not operate the tool if any part is missing. Replace the missing
part before operating. Failure to do so could result in a malfunction and
personal injury.
Remove the parts and accessories from the packaging and inspect for damage.
Make sure that all items in the parts list are included.
10
4 x 6 in. Metal Cutting Band Saw