Installation; Preparation For Positioning The Appliance; Electrical Connection; Water Drainage - Animo M100 Mode D'emploi

Masquer les pouces Voir aussi pour M100:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

CAUTION
Water always remains in the heating system: for this
reason the appliance must not be placed in an area
where the temperature can fall below freezing point.
3.2

Installation

3.2.1 Preparation for positioning the appliance

-
Position the appliance at buffet height on a firm, level base that can bear the weight of the
appliance when it is filled.
-
Position the appliance level and in such a way that it cannot cause any damage if it leaks.
-
The power connection must be located within half a metre of the appliance.
-
The owner must have these installation-technical preparations performed by qualified
engineers in accordance with general and local regulations.
-
The service engineer may only connect the appliance to the prepared connections.

3.2.2 Electrical connection

Supply voltages and frequencies can differ between countries. Check if the appliance is
suitable for connection to the local power mains. Check if the details on the type plate
correspond. Connect the appliance to an earthed wall socket.

3.2.3 Water drainage

The water reservoir has a maximum content of 2.7 litres. If the reservoir is overfilled, the
excess water will be discharged via the drain at the bottom of the appliance. Take this into
account when positioning the appliance.
WARNING
Ensure that the mains lead does not come into
contact with the hot plates (if present).

3.2.4 First time use

1.
Slide an empty basket filter (3) into the appliance and place an empty jug (with lid)
underneath it. NB! For the MT100(v) model leave the lid of the thermos jug with pump
open and leave the riser tube in the jug. Adjust the height of the MT100V before
positioning it. See 3.2.5.
2.
Pour one jug (water measuring cup, MT-model) of cold water into the cold water
reservoir (6).
3.
Wait for three minutes so that the entire heating system can de-aerate.
4.
Check if the on/off switches (1 + 2, if present) are at position O.
5.
Put the plug in the socket.
Animo
27

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

M102Mt100Mt100v

Table des Matières