• Wash your hands thoroughly after descaling the appliance.
• Always have repairs carried out by a qualified service engineer.
• The plug must be taken out of the socket if the appliance has to be opened for cleaning
or repairs.
The manufacturer cannot be held liable for losses caused as a result of failure to observe these
safety instructions.
Safeguards
The appliance is fitted with the following safeguards:
Dry-boil protection (14)
This appliance is equiped with a dry-boil protection. This protection triggers if the heating
element overheats owing to a fault. Once the fault has been resolved, the dry-boil protection
can be reset at the back of the appliance. The most common cause of the dry-boil protection
being triggered is not descaling the heating system in time.
If the heating system does not switch back on, proceed as follows:
1.
Allow the appliance to cool down.
2.
Unscrew the protective cap.
3.
Press the button which is now visible and firmly screw the protective cap back on.
If the dry-boil protection triggers owing to increased scale deposits, descale the appliance.
See chapter 5.2 Consult your dealer if the fault was caused by a problem other than the dry-boil
protection being triggered.
On/off switch (1)
The on/off switch is used to switch the appliance on and off. Remember that the appliance
can still be live after switching it off! For this reason you should always remove the plug from
the socket to render the appliance voltage-free.
Jug detector (9)
This appliance is fitted with a jug detector that operates the leak stop under the filter.
This jug detector also ensures that the appliance only makes coffee if there is a jug under the
filter. If the jug is removed during the coffee brewing process, the process will be interrupted
and the filter will stop leaking.
Animo