SECTION 6 - CARACTÉRISTIQUES GÉNÉRALES ET MAINTENANCE POUR L'OPÉRATEUR
82 °C (180 °F)
(TEMP . DU RÉS. D'HUILE
180° F (82° C)
HYD.)
(HYD. OIL TANK TEMP.)
TEMPÉRATURE
AMBIENT AIR
AMBIANTE
TEMPERATURE
120° F (49° C)
110° F (43° C)
100° F (38° C)
90° F (32° C)
80° F (27° C)
70° F (21° C)
60° F (16° C)
50° F (10° C)
40° F (4° C)
30° F (-1° C)
20° F (-7° C)
10° F (-12° C)
0° F (-18° C)
-10° F (-23° C)
-20° F (-29° C)
-30° F (-34° C)
-40° F (-40° C)
Figure 6-7. Spécifications de température de fonctionnement du moteur - Caterpillar - Fiche 2 de 2
3122543
IF EITHER OR BOTH CONDITIONS
SI UNE DE CES SITUATIONS OU LES DEUX SONT PRÉSENTES, JLG RECOMMANDE
EXIST JLG HIGHLY RECOMMENDS
FORTEMENT L'AJOUT D'UN REFROIDISSEUR D'HUILE HYDRAULIQUE
THE ADDITION OF A HYDRAULIC
(CONSULTER LE SERVICE APRÈS-VENTE DE JLG À CE PROPOS)
OIL COOLER (CONSULT JLG SERVICE
UTILISATION INTERDITE
NO OPERATION ABOVE THIS
AU-DESSUS DE CETTE
AMBIENT TEMPERATURE
TEMPÉRATURE AMBIANTE
SPÉCIFICATIONS
HYDRAULIQUES
HYDRAULIC
SPECIFICATIONS
NE PAS DÉMARRER LE CIRCUIT HYDRAULIQUE SANS DISPOSITIFS
DO NOT START UP HYDRAULIC SYSTEM
D'AIDE AU CHAUFFAGE AVEC L'HUILE HYDRAULIQUE MOBILE 424 EN
WITHOUT HEATING AIDS WITH MOBILE 424
DESSOUS DE CETTE TEMPÉRATURE
HYDRAULIC OIL BELOW THIS TEMPERATURE
DO NOT START UP HYDRAULIC SYSTEM
NE PAS DÉMARRER LE CIRCUIT HYDRAULIQUE SANS DISPOSITIFS D'AIDE AU CHAUFFAGE
WITHOUT HEATING AIDS AND COLD WEATHER
AVEC L'HUILE HYDRAULIQUE MOBILE DTE 13 EN DESSOUS DE CETTE TEMPÉRATURE
HYDRAULIC OIL BELOW THIS TEMPERATURE
NO OPERATION BELOW THIS
UTILISATION INTERDITE AU-DESSOUS DE
AMBIENT TEMPERATURE
CETTE TEMPÉRATURE AMBIANTE
– Élévateur JLG –
EXTENDED DRIVING WITH
CONDUITE PROLONGÉE AVEC DES TEMPÉRATURES DE
HYDRAULIC OIL TANK
TEMPERATURES OF 180° F
RÉSERVOIR D'HUILE HYDRAULIQUE DE 82 °C (180 °F) OU PLUS.
(82°C) OR ABOVE.
FONCTIONNEMENT PROLONGÉ À DES
PROLONGED OPERATION IN
TEMPÉRATURES D'AIR AMBIANT DE
AMBIENT AIR TEMPERATURES
38 °C (100 °F) OU PLUS.
OF 100° F (38° C) OR ABOVE.
NOTE:
1) RECOMMENDATIONS ARE FOR AMBIENT TEMPERATURES
CONSISTENTLY WITHIN SHOWN LIMITS
2) ALL VALUES ARE ASSUMED TO BE AT SEA LEVEL.
NOTE :
1. CES RECOMMANDATIONS SONT POUR
DES TEMPÉRATURES AMBIANTES
CONSTAMMENT DANS LES LIMITES
INDIQUÉES
2. TOUTES LES VALEURS SUPPOSENT QUE
LA MACHINE EST AU NIVEAU DE LA MER.
4150548-E