Channel Status Info LEDs
Each of the eight Control Channels has four LEDs for monitoring unit operating status.
Fig. 4
Channel Status Info LEDs
1
The green Power LED:
2
The yellow Status LED:
3
The red Alarm 1 LED:
4
The red Alarm 2 LED:
•
Channel is powered and enabled by the system.
•
Channel is in a fault condition.
•
Blinking LED (0.5 Hz):
Channel is disabled.
•
First alarm level is reached. It further indicates the specific
status:
•
Hz blinking:
First alarm level is reached, but not yet acknowledged
•
Steady:
First alarm level is acknowledged, but still inside alarm
range
•
0.5 Hz blinking:
First alarm is configured as latching. Measured value is
out of alarm level and not yet reset.
•
Second alarm level is reached. It further indicates specific
status:
•
4 Hz blinking:
Second alarm level is reached, but not yet acknowl-
edged
•
Steady:
Second alarm is acknowledged, but still inside alarm
range
•
0.5 Hz blinking:
Second alarm is configured as latching. Measured
value is out of alarm level and not yet reset.
GasGard XL
Description
US
11