Record Mode; Record Config; Encode Setup - gigamedia GGM CCKIT2C Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

EN

4.2 Record Mode

Control the recording status of each channel, through the [main menu] > [record mode] enter the record mode interface,
and also be right on the desktop directly into the shortcut menu.
The concrete operation, please refer to the chapter of "3.5.1 Record Mode"

4.3 Record Config

Set the recording parameters in the surveillance channel. The system is set 24
hours consecutive recording in the first startup. You can enter [main menu] > [re-
cording config] to set.
Note: There is at least one read-write hard disk (detail operation please refer to
chapter 4.5 HDD manage).
[Channel] Choose the corresponding channel number to set the channel. Choose
the all option to set the entire channels.
[Redundancy] Choose the redundancy function option to implement the file dou-
ble backup function. Double backup is writing the video files in two hard disks.
When you do the double backup, make sure that there are two hard disks instal-
led. One is read-write disk and the other is redundant disk. (refer to 4.5)
[Length] Set the time length of each video file. 60minutes is default value.
[Pre-recording] Record 1-30 seconds before the action. (time length is decided by the code stream)
[Recording control] Set video state: configuration, all or stop.
- Configuration: Record according to the set video type (common, detection and alarm) and time section
- All: Click the all button and the according channel is recording no matter the channel in any state
- Stop: Click the stop button and the according channel stops recording no matter the channel in any state
[Time section] Set the time section of common recording, The recording will start only in the set range.
[Recording type] Set recording type: regular, detection or alarm.
- Regular: Perform the regular recording in the set time section. The video file type is "R".
- Detection: Trigger the "motion detect", "camera mask" or "video loss" signal. When above alarm is set as opening recording, the "detection
- Alarme: Trigger the external alarm signal in the set time section. When above alarm is set as opening recording, the "detection recording"
state is on. The video file type is "A".
Note: Refer to chapter 4.8 to set corresponding alarm function.

4.4 Encode setup

Set the video/audio code parameter: video file, network surveillance and so on.
[Channel] Choose the channel number
[Compression] Standard H.264
[Resolution] Resolution type: D1/HD1/CIF/QCIF
[Frame Rate] P: 1 frame/s~25 frame/s - N: 1 frame/s~30 frame/s
[Bit Rate Type] You can choose constant code stream(CBR) or variable code
stream(VBR). When you choose the variable code stream there are six image
quality options.
[Bit Rate] Set the code stream value to modify the image quality. The larger code
stream value the better image quality. Reference range: D1 (1000~1500kbps),
CIF (400~600kbps), QCIF (64~512kbps)
[Video/Audio] When the icons are all in reverse displayed, the video file is video and audio multiplex stream.
[Auxiliary stream] Video/audio tick the enable auxiliary stream. It can achieve multi-channel recording and remote real-time
monitoring with ADSL internet, and for multi-channel playback at the same time.
[Channel number] First select the channel number, then select the following audio and video are open.
Resolution, frame rate, stream control, code stream value parameters and the independent channel the same settings.
44
recording" state is on. The video file type is "M".
Picture 4.1 Record config
Picture 4.2 Encode setup