Ptz Config; Alarm Setup; Motion Detect - gigamedia GGM CCKIT2C Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

EN

4.7 PTZ config

[Channel] Choose the dome camera input channel.
[Protocol] Choose the corresponding dome protocol. (PELCOD as an example)
[Address] Set as the corresponding dome address. Default: 1
(Note: The address must be consistent with the dome address)
[Baud rate] Choose the corresponding dome baud rate length. You can control
the PTZ and camera. Default: 115200.
[Date bit] Include 5-8 options. Default: 8.
Picture 4.15 PTZ setup
[Stop bit] Include 2 options. Default: 1.
[Check] Include odd check, even check, sign check, blank check. Default: void.

4.8 Alarm setup

Alarm functions include: Motion Detect, Video Blind, Video Loss, Alarm Input and Alarm Output.

4.8.1 Motion Detect

When system detects the motion signal that reaches the set sensitivity, the mo-
tion detect alarm is on and the linkage function is turned on.
Note : The Advanced button with the right mouse button.
[Channel Number] Choose the set motion detect channel.
[Enable / Activer] "■" means that the motion detect function is on.
[Sensitivity] Choose in the six options according to the sensitivity.
[Area] Click setup and enter the set area. The area is divided into PAL22X18.
Green block means the current cursor area. Yellow block means the dynamic
Picture 4.16 Motion detect
detect defensive area. Black block means the unfenced area. You can set the
area as followed, Drag the mouse and draw the area.
Black zone : motion
[Time section] Trigger the motion detect signal in the set time section. You can
detection activated
set according to week or set uniformly. Each day is divided into four time sections.
"■" means the set valid.
[Interval] Only one alarm signal is turned on even there are several motion detect
signals in the set interval.
Picture 4.17 Set the area
[Record Channel] Permet de sélectionner le nombre de caméras pour lesquelles
vous souhaitez lancer un enregistrement sur détection de mouvement
[Alarm output] Start the external equipment of corresponding linkage alarm
when the motion detect alarm is turned on.
[Delay] Delay a few moments and stop when the alarm state is turned off. The
range is 10~300 seconds.
[Recording channel] Choose the recording channel (multiple option supportive).
Trigger the video signal when the alarm is turned on.
Note: Set in the [recording setup] and perform the linkage recording. Start de-
tecting video files in the corresponding time section.
[Tour] "■" means that the selective channel is single window alternate patrol
preview. The interval is set in the [system setup] > [alternate patrol].
[PTZ linkage] Set the PTZ linkage when the alarm is turned on.
Picture 4.18 Set the time section
Note: PTZ linkage is set in the [shortcut menu] > [ PTZ control]. Set the patrol
between spots, trail patrol and so on.
4.19 PTZ linkage
www.gigamedia.net
48

Publicité

Chapitres

Table des Matières
loading

Table des Matières