by professionally qualified personnel with knowledge of the regulations in force for
installation and safety. ● The manufacturer disclaims all liability for persons,
animals or property if the guidelines provided in this chapter are not followed. ●
The power cable must be long enough to allow removal of the hob from the
worktop. ● Check that the voltage on the rating plate on the bottom of the product
corresponds to that of the domestic environment where it will be installed. ● Do
not use extension cords. ● The earth cable must be 2cm longer than the other
cables. ● If the product is not equipped with a power cable, use one with a
minimum conductor diameter of 2.5 mm2 for power up to 7200 Watt; for higher
power levels, the diameter must be 4 mm2. ● The temperature must not reach
50°C above room temperature anywhere along the cable. ● The product is
intended to be permanently connected to the mains, therefore, make the
connection to the mains using an approved omnipolar switch that guarantees
complete disconnection from the mains in category III overvoltage conditions, and
which is readily accessible after the installation.
● Please note! Before reconnecting the circuit to the mains power supply, make
sure that it is working correctly, always check that the power cable is correctly
installed.
● Please note! The interconnection cable must be replaced by the authorised
customer service representative or by a person with similar qualifications.
to connect the electrical appliance with the optional single-phase connection, the
existing power cord must be removed and replaced with another type of power
cord (not supplied) having the following specifications: single-phase
connection :cable H05V2V2-F 3G4.
POWER LIMITATION: the product is equipped with a Power Limitation function,
which allows a maximum power limit to be set (kw)
The setting must be made when the product is connected to the mains or when
the mains power itself is restored (within the following 2 minutes). Size the
electrical system protection according to the selected Power Limitation level. For
the Power Limitation setting sequence, see the Operation section of this manual.
WINDOWS KIT: The product can also be used in conjunction with a Window
sensor KIT (not supplied by the manufacturer). If the Window sensor KIT is
installed (only if used in DUCT-OUT mode), air extraction will halt every time the
window in the room, on which the KIT is applied, is closed. The KIT must be
electrically connected to the device by qualified and specialised technical
personnel. The KIT must be certified separately in accordance with the
safety standards for the component and its use with the device. Installation
must be carried out in accordance with current regulations for domestic
systems.
PLEASE NOTE: the wiring of the KIT to be connected to the product must be
part of a certified safety extra-low voltage (SELV) circuit. The manufacturer
of this device disclaims all liability for any inconvenience, damage or fires
21