Structure and function
Pilot pressure for control function B
Actuator
DN [mm]
size
15
ø 50 mm
20
25
15
20
ø 70 mm
25
32
20
25
ø 90 mm
32
40
50
40
ø 130 mm
50
65
Tab.7:
PilotpressureforCFB
* According to Pressure Equipment Directive for compressible fluids of
Group 1 (dangerous gases and vapours according to Art. 3, no. 1.3, letter
a, first dash)
The required minimum pilot pressure P min for control function B and I (flow
direction below seat) depends on the medium pressure.
The pressure graphs can be found in the operating instruc-
tions online at www.country.burkert.com
All manuals and user guides at all-guides.com
Type 2300
Pilot pressure [bar]
Max. per-
mitted
for medium pressure
Medium
pressure
0 bar
max
[bar]
5.1
7.0
5.1
7.0
5.1
7.0
5.2
6.5
5.2
7.0
5.2
7.0
5.2
7.0
2.4
3.8
2.4
4.6
2.5
5.7
2.5
7.0
2.5
7.0
2.7
4.9
2.7
6.2
2.7
7.0
16 (15 *)
7.5
General technical data
Media
Control medium
Flow media
16
9
Installation position
5
Degree of protection IP67 as per IEC 529/EN 60529
25
21
Control functions (CF) Valve seat always closes against medium
12
6
Control function A
25
Control function B
25
Control function I
25
25
14
8
INSTALLATION
25
25
8.1
Safety instructions
DANGER!
Risk of injury from high pressure in the system!
▶ Before loosening lines and valves, turn off the pressure and
vent the lines.
English
Neutral gases, air
Water, alcohols, oils, fuels, hydraulic
fluids, saline solutions, lyes, organic sol-
vents, vapour, air, neutral gases
any, preferably actuator face up
flow
closed by spring force in rest position
opened by spring force in rest position
Settings function of the alternating
pressurisation (not for actuator size
ø 50 mm in combination with Type 8696)