Rectangular Anti-tip Bracket
1
1. Measure 3
/
inches from back wall on right and left
2
side of cabinet cutout. Mark measurements on floor
and draw a straight line connecting marks.
2. Position anti-tip bracket.
• If range is installed beside cabinet(s), place anti-tip
bracket with back edge on line drawn on floor and
side of bracket against cabinet.
• If range is not installed beside cabinet(s), position
range where it will be installed. Draw a line along
side of range on floor from front to back. Remove
range. Place anti-tip bracket with back edge over
1
line drawn 3
/
inches from back wall and side of
2
bracket over line drawn along side of range on
floor.
• Anti-tip bracket can be installed on either right or
left side.
3. Mark 2 hole locations in anti-tip bracket.
4. Drill 2 holes.
• If drilling into wood, use a
• If drilling into concrete, use a
bit and insert plastic anchors.
5. Secure bracket to floor using screws supplied.
6. Slide range into position.
7. Remove range storage drawer and confirm anti-tip
bracket is engaged with range leveling leg.
All manuals and user guides at all-guides.com
3 1/2"
or
3
/
inch drill bit.
32
3
/
inch masonry drill
16
Line Voltage Requirements
Line voltage must not exceed rated voltage. Line voltage
less than rated voltage will result in slow heating. Wiring
system must conform to Canadian Electrical Code. Installation
must conform to all local, municipal and state building codes,
and local utility regulations. Range must be connected only to a
supply circuit as specified on rating plate of range. Electrical
outlet must be mounted on floor or wall within shaded area.
See figure below for electrical connection clearance area.
Wiring diagram is located on bottom side of storage drawer.
This range requires 3 wires, 120/240 Volts, 60 Hertz A.C.
See range rating plate for electrical ratings. House wiring
and fusing must comply with local wiring codes. If no
codes apply, wire according to Canadian Electrical
Codes.
5"
9
5"
18"
10"