Télécharger Imprimer la page

Amana CARDS801 Serie Mode D'emploi page 6

Publicité

Les langues disponibles

Les langues disponibles

Special Counter Top Conditions
Irregular Cabinet and Counter Top Heights
Counter tops such as ceramic tile tops cause cabinet and
counter top to be higher than 36 inches. Follow instructions
below when counter top is higher than 36 inches.
1. Raise leveling legs to maximum level.
2. Measure from floor to side trim. If measurement is
less than height of counter top floor must be
shimmed.
3. Shim floor using a piece of plywood same size as
range opening. Secure plywood to floor. Plywood
must be as secure as original flooring.
4. Install anti-tip bracket and slide range into place.
Island or Peninsula Installation
Island or peninsula installations with 24 inch deep base
cabinets must use flush back cabinets with no rear toe space
to avoid range interference. If a rear toe space is desired, use
27 inch or deeper base cabinets.
Slide-in Installation
Backrail
• For a manufactured counter top, with or without a
backsplash, make cutout keeping rear dimension
as illustrated. The backrail on back of range slides
over manufactured counter top creating a tight fit.
• Backrail may not reach backwall because of
counter top. Corner of backrail can be clipped off
with a pair of wire cutters for a tighter fit.
All manuals and user guides at all-guides.com
Duct Requirements
• Duct should be 6 inch round metal ducting. Island
• To ensure proper ventilation, duct work must not
• Curved fittings should not account for more than
• Flexible duct is not recommended because of
• Do not vent into an attic or crawl space. Duct range
• Flexible duct elbows are equal to twice as many
• Never install two elbow fittings next to each other.
• Seal all duct joints tightly using duct tape.
• For best performance, do not use over three 90°
• 6 inch transition duct provided must be
1-
3
/
"
4
6
or peninsula installations may require 3
duct.
exceed 60 equivalent feet.
50% of duct length.
irregular interior surface. If flexible duct is to be
used, one foot is equal to 2 feet of metal duct.
NEVER USE PLASTIC TYPE DRYER DUCTING.
outside.
feet as smooth metal elbows.
Two elbows installed together create a poor vent
path and insufficient ventilation.
Openings left in ducting allow smoke and odor to
escape inside house.
elbows.
mechanically secured to exhaust blower outlet.
Secure transition duct using two screws provided.
1
/
X 10 inch
4

Publicité