Télécharger Imprimer la page

SICK L4000 Mode D'emploi page 101

Système de barrières immatérielles de sécurité
Masquer les pouces Voir aussi pour L4000:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 347
en
Chapter 8
100
© SICK AG • Industrial Safety Systems • Germany • All rights reserved
Fault diagnosis
Display Cause
 Configuration
incorrect or
modified
 Supply voltage
too low
Operating Instructions
Remedying the error
 Check the configuration (number of
sensors, operating modes) of the
system.
 Switch the device off and on again.
 After the rectification of an error
perform a complete functional test as
defined in chapter 6.3 Test notes.
 Check the supply voltage and the
power supply. If necessary, replace
defective components.
 Switch the device off and on again.
8010009/1HGT/2022-11-21
L4000 system
Subject to change without notice