en
Chapter 9
104
© SICK AG • Industrial Safety Systems • Germany • All rights reserved
Technical data
Supply voltage
Power consumption
Electrical protection class III
Type
Safety Integrity Level
Category
Performance Level
13)
PFHd (mean probability
of a dangerous failure
per hour)
T
(mission time)
M
Wavelength
Aperture angle/
receiving angle
Diameter (optics)
Distance sender-
receiver
Ambient operating
temperature
Humidity (non-
condensing)
Storage temperature
Housing material
Optics
Enclosure rating
Response time
Input signal (sender only) HIGH: Transmission inactive
For continuous sending (that is alignment, PIN 4 of the sender not connected).
11)
Only in conjunction with safety evaluation device UE401.
12)
For detailed information on the exact design of your machine/system, please contact your local SICK
13)
representative.
minimum
19.2 V DC
24 V DC
Type 4 (IEC 61496-1)
SIL3 (IEC 61508, IEC 62061)
13)
Category 4 (EN ISO 13849-1)
PL e (EN ISO 13849-1)
–10
2.9×10
20 years (EN ISO 13849)
660 nm (red)
12 mm
0 m
–20 C
15 %
–25 C
Plastic or nickel plated brass
Plastic
IP 67
LOW —
HIGH: 0.4 ms
HIGH —
LOW: 0.6 ms
LOW or open circuit: Transmission active
Operating Instructions
L4000 system
typical
maximum
28.8 V DC
60 mA
11)
(Sender)
30 mA
(Receiver)
12)
2.5
axial 10 m
radial 5 m
+55 C
95 %
+75 C
8010009/1HGT/2022-11-21
Subject to change without notice