Operating Instructions
L4000 system
8010009/1HGT/2022-11-21
Subject to change without notice
Fault diagnosis
Display Cause
EDM error (the
or
flashing
indicates that
the internal
restart interlock
is not active)
Configuration of
the sensors
connected is
incorrect
System error
Overcurrent
switching
output 1
Short-circuit
switching
output 1
Short-circuit
switching
output 1
Overcurrent
switching
output 2
Short-circuit
switching
output 2
Short-circuit
switching
output 2
Short-circuit
between
switching output
1 and 2
Is only detected with safety switching outputs (OSSDs) enabled.
1)
© SICK AG • Industrial Safety Systems • Germany • All rights reserved
Remedying the error
Check the contactors or switching
devices and the wiring and rectify the
wiring error.
If is displayed switch the device off
and on again.
Check the connection of the sensors
to the switching amplifier.
Switch the device off and on again.
Replace the safety evaluation device
UE401.
1)
at
Check the contactor or the switching
devices. Replace them if necessary.
Check the wiring for short-circuit to
0 V.
Switch the device off and on again.
1 )
at
Check the wiring for short-circuit to
24 V.
Switch the device off and on again.
1)
at
Check the wiring for short-circuit to
0 V.
Switch the device off and on again.
at
Check the contactor or the switching
1)
devices. Replace them if necessary.
Check the wiring for short-circuit to
0 V.
Switch the device off and on again.
at
Check the wiring for short-circuit to
1)
24 V.
Switch the device off and on again.
at
Check the wiring for short-circuit to
1)
0 V.
Switch the device off and on again.
Check the wiring and rectify the error.
1)
Switch the device off and on again.
en
Chapter 8