Mounting Plate Installation (For Typical Drywall Construction) - Napoleon Plazmafire 48 Manuel D'installation Et Operation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

5.1

mounting plate installation (for typical drywall construction)

Level and affix the mounting 'template' to the wall at the desired location and height. The centre of the
A.
vent pipe must be centered between wall studs.
Using the 'template', mark the holes for the vent, gas and electrical inlets, and mounting screw locations
B.
(must be into studs). See "MINIMUM CLEARANCES TO COMBUSTIBLES" section.
NOTE : Use the appropriate cutout on the mounting 'template' for combustible material.
Remove the mounting 'template' from the wall and cut/drill the required holes as marked.
C.
Form the vent shield until the four screw holes overlap then secure from the inside out.
D.
NOTE : Securing from the outside in will puncture venting.
Bend the four tabs on the firestop spacer outwards. Slide the vent shield into the firestop spacer aligning
E.
the holes within the tabs and secure.
The vent shield and firestop spacer have been designed to accommodate a maximum wall depth of 14"
F.
(35.6cm). The vent shield must extend the full depth of the combustible wall. Trim the vent shield to suit
as necessary.
Apply a bead of caulking (not supplied) to the flange perimeter and wings of the firestop plate. Install the
G.
wall mounting plate assembly with the vent shield into the wall.
NOTE : Ensure the assembly is levelled.
Look through slotted holes on the wall mounting plate for pre-marked stud locations and secure wall
H.
mounting plate assembly using a minimum of four screws (minimum one screw per corner must be
mounted to a wall stud).
NOTE : For typical stud wall with drywall installation, fasteners are provided and must engage
into frame/studs.
See the following sections up to the "FINISHING" section for venting and mounting instructions.
I.
Bottom of appliance must maintain 6" clearance
to combustible. See "MINIMUM CLEARANCE TO
COMBUSTIBLES" section.
(FIG. 2)
(FIG. 4)
TYPE 1 (X4)
FIG.1
TYPE 3 (X4)
CAULKING
REAR VIEW
FIG.3
NOTE : For ease of installation, we recommend
installing fasteners into the 4 outer slots.
Fasteners must be secured to a stud.
installation
(FIG. 1)
(FIG. 3)
TYPE 1 (X4)
TYPE 4 (X4)
W415-1606 / D / 08.23.18
EN
FIG.2
FIG.4
17