Typical Venting Installation - Napoleon Ascent BX42 Manuel D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

venting requirements
EN
2.1

typical venting installation

base of air collar
Special vent installation (periscope termination)
Use the periscope kit to locate the air termination above grade. The periscope must be installed so that when
fi nal grading is completed, the bottom air slot is located a minimum 12" (30.5cm) above grade. The maximum
allowable vent length is 10' (3m) for a fi replace and 8' (2m) for a stove.
*See "venting requirements" and
"venting installation" sections.
14
W415-2920 / B / 04.26.22
24" (61cm)
Maximum
12" (30.5cm)
Minimum
Minimum plus
TOP VENT
30" (76.2cm)
Minimum
base of air collar
!
45 5/8"
(115.8cm)
rise*
!
TOP VENT
WARNING
The fi rst 2 feet of outer 8" (203mm)
diameter vent pipe from the ap-
pliance must be wrapped in the
1" (25mm) thick insulation sleeve
(supplied).
20" (50.8cm)
Maximum
24 1/8" (61.3cm)
Minimum plus rise*
REAR VENT
12"
(30.5cm)
minimum
to grade
WARNING
The fi rst 2 feet of outer 8" (203mm)
diameter vent pipe from the ap-
pliance must be wrapped in the
1" (25mm) thick insulation sleeve
(supplied).

Publicité

Table des Matières
loading

Table des Matières