Gas Installation; Mobile Home - Napoleon Plazmafire 48 Manuel D'installation Et Operation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

installation
EN
5.5

gas installation

WARNING
!
Risk of fi re, explosion, or asphyxiation. Ensure there are no ignition sources such as sparks or open fl ames.
Support gas control when attaching gas supply pipe to prevent damaging gas line.
Always light the pilot whether for the fi rst time or if the gas supply has run out with the glass door opened
or removed. Purging of the gas supply line should be performed by a qualifi ed service technician. Ensure
that a continuous gas fl ow is at the burner before closing the door. Ensure adequate ventilation. For gas and
electrical locations, see "appliance dimensions" section.
All gas connections must be contained within the appliance when complete.
High pressure will damage valve. Disconnect gas supply piping before testing gas line at test pressures above
1/2 PSIG.
Valve settings have been factory set, do not change.
Installation and servicing to be done by a qualifi ed installer.
Move the appliance into position and secure.
If equipped with a fl ex connector, the appliance is designed to accept a 1/2" (13mm) gas supply. Without the
connector, it is designed to accept a 3/8" (9.5mm) gas supply. The appliance is equipped with a manual shut
off valve to turn off the gas supply to the appliance.
Connect the gas supply in accordance to local codes. In the absence of local codes, install to the current
CAN/CSA-B149.1 Installation Code in Canada or to the current National Fuel Gas Code, ANSI Z223.1 / NFPA
54 in the United States.
When fl exing any gas line, support the gas valve so that the lines are not bent or kinked.
The gas line fl ex-connector should be installed to provide suffi cient movement for shifting the burner assembly
on its side to aid with servicing components.
Check for gas leaks by brushing on a soap and water solution. Do not use open fl ame.
5.6

mobile home

This appliance must be installed in accordance with the manufacturer's instructions and the Manufactured
Home Construction and Safety Standard, Title 24 CFR, Part 3280, in the United States or the Mobile Home
Standard, CAN/CSA Z240 MH Series, in Canada. This appliance is only for use with the type(s) of gas
indicated on the rating plate.
This mobile/manufactured home listed appliance comes factory equipped with a means to secure the appliance. Built
in appliances are equipped with 1/4" (6.4mm) diameter holes located in the front left and right corners of the base.
Use appropriate fasteners, inserted through the holes in the base to secure. For free standing products contact your
local authorized dealer / distributor for the appropriate securing kit. For mobile home installations, the appliance must
be fastened in place. It is recommended that the appliance be secured in all installations. Always turn off the pilot and
the fuel supply at the source, prior to moving the mobile home. After moving the mobile home and prior to lighting the
appliance, ensure that the logs are positioned correctly.
This appliance is certifi ed to be installed in an aftermarket permanently located, manufactured (mobile) home,
where not prohibited by local codes.
This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible
for use with other gases, unless a certifi ed kit is used.
Conversion Kits
This appliance is fi eld convertible between Natural Gas (NG) and Propane (P).
To convert from one gas to another, consult your Authorized dealer/distributor.
22
W415-1606 / D / 08.23.18
21.1
20.1

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Whd48nWhd48p

Table des Matières