Reset; Technical Data; General Declaration Of Conformity - Selve SEL Plus Notice De Réglage

Masquer les pouces Voir aussi pour SEL Plus:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Reset/Technical data

5. Reset

For resetting the motor please use the setting switch for electronic motors.
Both end positions have to be set, so the movement isn't interrupted twice during
operation.
By pressing the E button for 1 second the motor will be put into the automatic setup-
mode. Restart setting the end positions (4.4.1. to 4.4.3.).

6. Technical data

Series
1/6
1/10
2/7
2/10
2/15
2/20
2/30
2/40
2/50
Not all motor types are available in all series and torques. The motors have a 2.5 m
power line by default.
Information for all motor types:
Nominal voltage:
Safety class:
Operating time:
Subject to change without prior notice!

7. General declaration of conformity

SELVE GmbH & CO. KG company, hereby declares that the SEL Plus and SES are in
conformity with the basic requirements and other relevant provisions of the Directive
73/23/EWG and 89/336/EWG. The declaration of conformity can be looked up at
www.selve.de.
Torque
Rotation speed
Nm
Rpm
6
15
10
15
7
17
10
17
15
17
20
17
30
17
40
17
50
12
230 V AC/50 Hz
IP 44
4 min.
31
Power Input
Output
A
0.45
0.45
0.41
0.45
0.66
0.75
0.95
1.50
1.50
GB
W
105
105
95
105
152
172
220
345
345